检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵磊 肖武 Zhao Lei;Xiao Wu(China Aviation Planning and Design Institute(Group)Co.,Ltd.,Beijing,China;不详)
机构地区:[1]中国航空规划设计研究总院有限公司
出 处:《暖通空调》2021年第10期18-21,共4页Heating Ventilating & Air Conditioning
摘 要:结合实际工程,对大温差蓄能式地源热泵系统的应用进行了全年运行费用及地埋管地源热泵系统热平衡计算。结果表明,大温差蓄能式地源热泵系统的运行费用低,节能及经济性效果明显。该工程采用了冰蓄冷、水蓄热一体复合式蓄能系统,可实现冬夏两季蓄能,蓄能效率大幅度提高,节省了冷热源系统运行费用,同时减少了蓄能设备占用空间。Combining with a practical project, calculates the annual operation cost and heat balance of the buried pipes of the ground-source heat pump system with large temperature difference energy storage. The results show that the ground-source heat pump system with large temperature difference energy storage has the advantages of low operation cost, obvious energy saving and economic effect. The project adopts the integrated composite energy storage system of ice cool storage and water heat storage, which can realize energy storage in winter and summer, greatly improve the energy storage efficiency, save the operation cost of cold and heat source system, and reduce the space occupied by energy storage equipment.
关 键 词:地源热泵 冰蓄冷 水蓄热 热平衡 大温差 运行费用 公共建筑
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]