制药厂房洁净空调系统能耗监测及分析方法  被引量:6

Energy consumption monitoring and analysis method of clean air conditioning systems in pharmaceutical factories

在线阅读下载全文

作  者:代丹 林绿渊 肖武 郜义军 张改[2] Dai Dan;Lin Lüyuan;Xiao Wu;Gao Yijun;Zhang Gai(China Aviation Planning and Design Institute(Group)Co.,Ltd.,Beijing,China;不详)

机构地区:[1]中国航空规划设计研究总院有限公司 [2]成都生物制品研究所有限责任公司 [3]北京华勤洁净科技有限公司

出  处:《暖通空调》2021年第10期33-38,32,共7页Heating Ventilating & Air Conditioning

基  金:国家重点研发计划项目“洁净空调厂房的节能设计与关键技术设备研究”(编号:2018YFC0705204)。

摘  要:以某制药厂房为例,分别对制药厂房洁净空调系统中空调机组和制冷站的能耗实地监测及统计分析方法进行了研究。从测试原理、仪器、测点设置和数据采集4个方面详细介绍了空调系统的能耗监测方法。结合实际项目,在介绍能耗监测内容的基础上,提出了空调机组耗冷量、耗热量及风机耗电量的分析方法。通过对制冷站冷水机组、冷水泵、冷却水泵和冷却塔能耗监测方法的探讨,给出了其能耗统计分析方法。总结了一套行之有效的制药厂房洁净空调系统能耗实地测试和数据分析方法。Taking a pharmaceutical factory as an example, studies the methods of on-the-spot monitoring and statistical analysis of energy consumption of the air conditioning units and refrigeration stations in the clean air conditioning system of pharmaceutical factory. Presents the energy consumption monitoring method of the air conditioning system in detail from four aspects of test principles, instruments, test point setting and data acquisition. Combined with the actual project, on the basis of presenting the content of energy consumption monitoring, proposes the analysis method of air conditioning unit cold consumption, heat consumption and fan power consumption. Through the discussion of energy consumption monitoring methods of chillers, chilled water pumps, cooling water pumps and cooling towers in refrigeration station, gives the statistical analysis method of energy consumption. Summarizes a set of effective field test and data analysis methods for energy consumption of clean air conditioning systems in the pharmaceutical factory.

关 键 词:制药厂房 洁净空调系统 制冷站 能耗监测 能耗分析 

分 类 号:TQ460.8[化学工程—制药化工] TU831.8[建筑科学—供热、供燃气、通风及空调工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象