核电厂通风系统运行风量对碘吸附器性能的影响  被引量:2

Effect of air flow rate on performances of iodine adsorber in ventilation system of nuclear power plants

在线阅读下载全文

作  者:陈建利[1] 陈荣添 高琳锋[1] 李永国[1] 韩丽红[1] 梁飞[1] 李彦樟 张治权 Chen Jianli;Chen Rongtian;Gao Linfeng;Li Yongguo;Han Lihong;Liang Fei;Li Yanzhang;Zhang Zhiquan(China Institute for Radiation Protection,Taiyuan,China;不详)

机构地区:[1]中国辐射防护研究院 [2]福建福清核电有限公司

出  处:《暖通空调》2021年第10期150-152,12,共4页Heating Ventilating & Air Conditioning

摘  要:核电厂通风系统中的碘吸附器性能受到多种因素的影响,运行风量是其中之一。推导了碘吸附器净化系数、系统净化系数和泄漏率的关系,并在实验数据基础上,利用推导公式计算了系统的泄漏率,同时分析了风量对三者的影响。结果表明,在本文实验条件下,随运行风量的增大,系统净化系数增大、泄漏率减小。The operating air flow rate is one of the influencing factors on the performance of iodine adsorber in the ventilation system of nuclear power plants.Derives the relationship among the purification coefficient of iodine adsorber,system purification coefficient and leakage rate.Based on the experimental data,calculates the leakage rate of the system by the derived formula,and analyses the influence of air flow rate on the three factors.The results show that under the conditions of this experiment,the system purification coefficient increases with the increase of air flow rate,while the leakage rate decreases.

关 键 词:通风系统 碘吸附器 运行风量 净化系数 泄漏率 

分 类 号:TM623[电气工程—电力系统及自动化]

 