新型改性酚醛保温板系统与岩棉保温板系统的燃烧性能对比研究  被引量:1

A comparative study on combustion performance of new modified phenolic insulation board system and rock wool insulation board system

在线阅读下载全文

作  者:李碧英 颜明强 Li Biying;Yan Mingqiang(Sichuan Fire Research and Technology Research Institute of MEM)

机构地区:[1]应急管理部四川消防研究所

出  处:《今日消防》2021年第10期5-8,共4页

基  金:国家重点研发计划项目(2018YFC0807600,2018YFC0807603,2018YFC0807603-1);应急管理部四川消防研究所基本科研业务费项目:装配式钢结构防火保温装饰一体化技术研究(项目编号:20188808Z)。

摘  要:文章采用《建筑外墙外保温系统的防火性能试验方法》(GB/T 29416-2012)对新型改性酚醛保温板系统和岩棉保温板系统的防火性能进行了对比研究,通过测试保温层内部温度表明,改性酚醛保温板系统燃烧室顶正上方1.2 m高度处内部温度为144.3℃,岩棉保温板系统燃烧室顶正上方1.2 m高度处内部温度为235.1℃;燃烧室顶正上方4.1 m高度处外部温度为462.4℃,岩棉保温板系统燃烧室顶正上方4.1 m高度处外部温度为422.7℃;燃烧室顶正上方4.1 m高度处内部温度为31.5℃,岩棉保温板系统燃烧室顶正上方4.1 m高度处内部温度为85.3℃.在采用《建筑外墙外保温系统的防火性能试验方法》(GB/T 29416-2012)同等火源功率下,两种保温系统的燃烧性能基本相当。In this paper,a comparative study was conducted on the combustion performance of new modified phenolic insulation system and rock wool insulation system by means of test Methods for Fire Performance of Building External Wall Thermal Insulation System(GB/T 29416-2012).The test of the internal temperature of the insulation layer shows that the internal temperature of the modified phenolic insulation board system 1.2 meters above the top of the combustion chamber is 144.3℃,and that of the rock wool insulation board system 1.2 meters above the top of the combustion chamber is 235.1℃.The test of the external temperature of the insulation layer shows that the internal temperature of the modified phenolic insulation board system 4.1 meters above the top of the combustion chamber is 462.4℃,and that of the rock wool insulation board system 4.1 meters above the top of the combustion chamber is 422.7℃.The test of the internal temperature of the insulation layer shows that the internal temperature of the modified phenolic insulation board system 4.1 meters above the top of the combustion chamber is 31.5℃,and that of the rock wool insulation board system 4.1 meters above the top of the combustion chamber is 85.3℃.Under the same fire power(GB/T 29416-2012),the combustion performance of the two thermal insulation systems is basically equivalent.

关 键 词:酚醛保温板 岩棉保温板 燃烧性能 

分 类 号:U214.45[交通运输工程—道路与铁道工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象