作 者:谢世杰 许卫荣 王强 廖晓玲 柳青 谷小红 XIE Shijie;XU Weirong;WANG Qiang;LIAO Xiaoling;LIU Qing;GU Xiaohong(College of Quality and Safety Engineering,China Jiliang University,Hangzhou 310018,China;College of Mechanical and Electrical Engineering,China Jiliang University,Hangzhou 310018,China;Huzhou Special Equipment Testing and Research Institute,Huzhou 313000,China;Hangzhou Special Equipment Testing and Research Institute,Hangzhou 310018,China)
机构地区:[1]中国计量大学质量与安全工程学院,浙江杭州310018 [2]中国计量大学机电工程学院,浙江杭州310018 [3]湖州市特种设备检测研究院,浙江湖州313000 [4]杭州市特种设备检测研究院,浙江杭州310018
出 处:《河南科技大学学报(自然科学版)》2022年第1期46-51,M0005,共7页Journal of Henan University of Science And Technology:Natural Science
基 金:国家重点研发基金项目(2018YFF0214700);杭州市科技局农业与社会发展项目(20201203B159)。
摘 要:基于全矩阵数据捕获(FMC),利用全聚焦(TFM)成像技术,对高密度聚乙烯(HDPE)试块中不同深度(10~50 mm)的预制横通孔缺陷进行了全聚焦成像实验分析。在MATLAB软件中编写了全聚焦成像算法,并将全聚焦成像效果与超声相控阵扇形扫描成像效果进行比较。研究结果表明:全聚焦超声成像方法对于HDPE试块内部的横通孔缺陷,能够较好地实现缺陷位置的定位。在5 MHz频率探头的条件下,检测深度达到50 mm以上,深度定位误差在2 mm以内。相比于超声相控阵扇扫方法,本文方法的∅1 mm缺陷最大幅值标准差从16.8 dB降低到了7.5 dB,∅2 mm缺陷的最大幅值标准差从21.0 dB降低到了6.2 dB,有2~3倍的提升。Based on full matrix capture data,the total focusing method(TFM)imaging technology was used to image and analyze the defects of side-drilled holes with different depths(10~50 mm)in high density polyethylene(HDPE)test block.In Matlab software,the total focusing method algorithm was coded.The TFM imaging results was compared with ultrasonic phased sector scanning data.The experimental results show that the TFM is able to locate the defects position of the side-drilled holes in the HDPE block.For the 5 MHz probe in test,the TFM algorithm can detect the defects in HDPE with depth larger than 50 mm.The defect depth location error is less than 2 mm.Compared with the ultrasonic phased sector scanning method,the maximum amplitude standard deviation of 1 mm defects(∅1 mm)is decreased from 16.8 dB to 7.5 dB,and the maximum amplitude standard deviation of 2 mm defect(∅2 mm)is decreased from 21.0 dB to 6.2 dB.The signal-noise-ration(SNR)has improved about 2~3 times.
分 类 号:TG115.28[金属学及工艺—物理冶金]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.221.83.23