检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钮志峰 程途[1] NIU Zhifeng;CHENG Tu(Jiangsu Huadian Qishuyan Power Generation Co.,Ltd.,Changzhou 213011)
机构地区:[1]江苏华电戚墅堰发电有限公司,江苏常州213011
出 处:《电力安全技术》2021年第10期32-34,共3页Electric Safety Technology
摘 要:通过一起发电机出口开关液压弹簧操作机构储能失去的应急处理及故障原因分析,验证了应急处理措施的正确性,找出了开关分闸电磁阀未关闭到位是引起本次故障的主要原因,并提出了相应的措施建议,为此类型设备的运维和故障处理提供参考。Through the emergency treatment and fault cause analysis on the energy storage failure of the hydraulic spring operating mechanism of the generator outlet switch,the correctness of the emergency treatment measures is verified.The main cause of the fault is found that the switch opening solenoid valve is not closed in place,and the corresponding measures and suggestions are put forward,which provides a certain reference for the operation and maintenance and fault treatment of this type of equipment.