机构地区:[1]四川大学国家生物医学材料工程技术研究中心,四川省成都市610064 [2]四川医疗器械生物材料和制品检验中心,四川省成都市610064
出 处:《中国组织工程研究》2022年第22期3474-3479,共6页Chinese Journal of Tissue Engineering Research
基 金:国家重点研发计划(2018YFC1106800),课题负责人:梁洁;四川省重点研发项目(2020YFS0462),项目负责人:袁暾。
摘 要:背景:胸主动脉支架系统类器械一般由覆膜支架和金属裸支架及相应的输送系统构成,由于此类器械结构的复杂性,导致临床上可能带来更多关于血栓安全性的担忧。目的:为覆膜支架和裸支架联合使用的植入血管类器械上市前安全性评价的设计和结果分析提供更完整的思路。方法:选取3只实验猪,均植入胸主动脉支架系统,该系统包括胸主动脉支架系统输送器、胸主动脉支架系统覆膜支架、胸主动脉支架系统裸支架三部分,将覆膜支架植入实验动物的降主动脉段,并导入胸主动脉裸支架衔接于胸主动脉覆膜支架的远端,术中,对回撤至体外的输送器部分观察其表面血栓形成情况。术后7 d,取胸主动脉支架系统覆膜支架、裸支架与输送器部分,进行扫描电镜观察;取胸主动脉支架系统裸支架和覆膜支架接触部位血管,进行组织学观察。结果与结论:(1)大体观察显示,实验动物重要脏器未见血栓形成和血栓相关病变,植入部位血管的管腔中未见血栓性闭塞。(2)扫描电镜显示,覆膜支架系统输送器与裸支架系统输送器表面均可见几微米至上百微米大小的血栓分布,覆膜支架、裸支架表面及与支架接触的血管表面均可见几微米至几百微米大小的血栓分布。(3)组织学观察显示,覆膜支架接触部位血管内膜增生,新生组织大多由纤维蛋白网络大量红细胞构成,组织内部有炎性细胞浸润,少量新生组织边缘可见炎性细胞聚集,新生组织中局部有新生小血管形成;裸支架接触部位血管内膜增生,新生组织多由坏死的细胞构成,局部有聚集的炎性细胞。(4)结果表明,覆膜支架和裸支架联合使用的植入类器械植入后对血管产生的影响因组成不同而不同,需要考虑支架本身组成的特殊性,结合其临床使用方式,针对各组成部分进行分别评价分析。BACKGROUND:The thoracic aortic stent system instruments generally consist of covered stent,bare metal stent and corresponding delivery system.They may trigger more concerns about the safety of thrombosis in clinical practice by reason of the complexity in structure of such instruments.OBJECTIVE:To provide a more rational idea for the design and analysis of premarket safety evaluation of such implantable vascular devices combined with covered stent and bare stent.METHODS:Three experimental pigs were selected and implanted with the thoracic aortic stent system.The system includes the thoracic aortic stent system transporter,covered stent and bare stent.The coated stent was inserted into the descending aorta of the experimental pig,and the bare stent was subsequently led in to concatenate the distal end of the covered stent.During the operation,the surface thrombosis of the extracorporeal part of the transporter was observed.Seven days after the surgery,the covered stent,transporter and bare stent were taken out to perform scanning electron microscopy.Meanwhile,the vessels contacted the bare stent and coated stent were separated to process histological observation.RESULTS AND CONCLUSION:(1)Gross observation displayed that no thrombosis or thrombosis-related lesions were observed in the important organs of the experimental pigs,and no thrombotic occlusion was observed in the lumen of the blood vessels at the implantation site.(2)Scanning electron microscopy showed that thrombosis of several microns to hundreds of microns could be seen on the surface of the transporter of the coated stent system and the bare stent system,and thrombosis of several microns to hundreds of microns could be seen on the surface of the coated stent,bare stent and the vascular surface contacted with the stent.(3)Histological observation showed intimal hyperplasia at the contact site of the coated stent.Most of the new tissue was composed of fibrin network and a large number of red blood cells.Simultaneously,inflammatory cells were infiltrated
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...