作  者:梅国健 李传生[2] 王家福[2] 赵叶铭 董平 邵海明[2] 姚燕[1] MEI Guo-jian;LI Chuan-sheng;WANG Jia-fu;ZHAO Ye-ming;DONG Ping;SHAO Hai-ming;YAO Yan(China Jiliang University,Hangzhou,Zhejiang 310018,China;National Institute of Metrology,Beijing 100029,China;Beijing University of Science and Technology Information,Beijing 100192,China;Shanxi Institute of Metrology,Taiyuan,Shanxi 030021,China;Zhejiang Province Institution of Metrology,Hangzhou,Zhejiang 310018,China)

机构地区:[1]中国计量大学,浙江杭州310018 [2]中国计量科学研究院,北京100029 [3]北京信息科技大学,北京100192 [4]山西省计量科学研究院,山西太原030021 [5]浙江省计量科学研究院,浙江杭州310018

出  处:《计量学报》2021年第10期1343-1348,共6页Acta Metrologica Sinica

基  金:国家重点研发计划(2016YFF0201202,2016YFF0102404)。

摘  要:针对变压器工频短路电流测量需求,研究了外积分式罗氏线圈技术和光纤电流传感技术。建立了2种传感器的低频数学模型,基于MATLAB/Simulink仿真计算传感器对工频短路电流的响应特性,结果表明:罗氏线圈对工频短路电流的测量精度受其下截止频率影响,下截止频率越低,测量精度越高;光纤电流传感器理论上可以精确复现工频短路电流。采用多种电流传感器进行变压器工频短路电流现场对比测试,结果表明:电流比较仪、光纤电流传感器及下截止频率为0.02 Hz的罗氏线圈测得的电流波形吻合较好,而下截止频率为0.2 Hz的罗氏线圈测量结果出现了明显的偏移,且无法归零,与仿真分析结论基本一致。对于外积分式罗氏线圈,为保证高精度测量,建议下截止频率应低于0.1 Hz;光纤电流传感器具有极好的直流及低频响应特性,是工频短路电流高精度测量的理想方案。Aiming at the requirements of transformer power frequency short-circuit current measurement,the external integral Rogowski coil technology and fiber-optic current sensing technology are studied. The low-frequency mathematical models of the two sensors are established which based on MATLAB/Simulink to calculate the response characteristics of the sensor to the power-frequency short-circuit current. The results show that the measurement accuracy of the Rogowski coil for the power-frequency short-circuit current is affected by its lower cut-off frequency. If the cut-off frequency is lower,the measurement accuracy will be higher. The optical fiber current sensor can theoretically accurately reproduce the power frequency short-circuit current. Multiple current sensors are used for the field comparison test of the transformer’s power frequency short-circuit current. The results show that the current waveforms measured by the AC/DC current comparator,the fiber-optic current sensor,and the Rogowski coil with a lower cut-off frequency of 0.02 Hz agree well,the measurement result of the lower cut-off frequency in Rogowski coil at 0.2 Hz shows a significant deviation and could not be reset to zero,which is consistent with the simulation analysis conclusion. It is recommended that the lower cut-off frequency should be lower than 0.1 Hz for the external integral Rogowski coil in order to ensure high-precision measurement;fiber-optic current sensor has excellent DC and low-frequency response characteristics,it is an ideal scheme for high-precision measurement of power frequency short-circuit current.

关 键 词:计量学 工频短路电流 光纤电流传感器 罗氏线圈 

分 类 号:TB971[一般工业技术—计量学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象