阜阳华润电力有限公司2×640 MW机组节能提效改造后顶棚过热器泄漏分析  

Analysis of Leakage of Roof Superheater after Fuyang Huarun Resources Power Limited Company 2×640 MW Unit Energy-saving and Efficiency-increasing Transformation

在线阅读下载全文

作  者:胡涛 HU Tao(Huainan Electric Power Maintenance Co., Ltd., Huainan 232007, China)

机构地区:[1]淮南电力检修有限责任公司,淮南232007

出  处:《应用能源技术》2021年第11期38-44,共7页Applied Energy Technology

摘  要:主蒸汽温度由543℃提高至571℃,主蒸汽流量1950 t/h降低至1885 t/h,主汽压力不变,再热器温度压力基本不变。改造范围主要是调整过热器系统受热面积,并进行材料更换或升挡,同时根据汽水参数变化情况,对再热器和省煤器等受热面进行调整,相应管道、阀门也随之进行更换,维持原超临界锅炉方案炉膛尺寸不变,保持尾部烟道的中间隔墙不变。改造后顶棚过热器发生泄漏一次。The main steam temperature is increased from 543℃to 571℃,the main steam flow rate is reduced from 1950 t/h to 1885 t/h,the main steam pressure remains unchanged,and the reheater temperature and pressure remain basically unchanged.The scope of the transformation is mainly to adjust the heating area of the superheater system,and carry out material replacement or upshifting.At the same time,according to the changes of the soda and water parameters,the heating surfaces such as the reheater and the economizer are adjusted,and the corresponding pipes and valves are also replaced accordingly.Keep the original furnace size of the supercritical boiler plan unchanged,and keep the middle partition wall of the tail flue unchanged.After the renovation,the roof superheater leaked once.

关 键 词:超临界 升级提效 改造 泄漏 

分 类 号:TK223.3[动力工程及工程热物理—动力机械及工程]

 