灯泡贯流泵典型故障诊断分析  被引量:1

Typical fault diagnosis analysis of bulb tubular pump

在线阅读下载全文

作  者:施伟 蔡瑞民 李松柏 孙涛 成立[2] 罗灿 SHI Wei;CAI Ruimin;LI Songbai;SUN Tao;CHENG Li;LUO Can(The Eastern Route of South to North Water Diversion,Jiangsu Water Resources Co.,Ltd.,Nanjing 210029,China;College of Hydraulic Science and Engineering,Yangzhou University,Yangzhou 225009,China)

机构地区:[1]南水北调东线江苏水源有限责任公司,江苏南京210029 [2]扬州大学水利科学与工程学院,江苏扬州225009

出  处:《江苏水利》2021年第11期19-22,27,共5页Jiangsu Water Resources

基  金:国家自然科学基金(51779214);江苏省南水北调科技研发项目(SSY-JS-2020-F-43);江苏省水利科技项目(2020030)。

摘  要:针对灯泡贯流泵存在的典型故障,介绍了大型灯泡贯流泵典型故障的发生原因以及解决措施,从典型故障案例出发,介绍了灯泡贯流泵泵站运行典型故障的预防措施,结论可为同类型泵站的运行管理提供参考。Aiming at the typical faults of bulb tubular pump,the causes and solutions of typical faults of large bulb tubular pump were introduced.Starting from the typical fault cases,the preventive measures of typical faults of bulb tubular pump pumping station were introduced.The conclusion could provide reference for the operation and management of the same type of pumping station.

关 键 词:泵站 典型故障 灯泡贯流泵 