机构地区:[1]西安交通大学第一附属医院结构性心脏病科,陕西西安710061 [2]空军军医大学西京医院超声科,陕西西安710032
出 处:《心脏杂志》2021年第4期390-395,共6页Chinese Heart Journal
摘 要:目的评价经胸超声心动图(TTE)在膜周部室间隔缺损(pmVSD)介入治疗及中远期随访中的应用价值。方法TTE诊断pmVSD患者302例(男,129),年龄(19±16)岁。术前TTE多切面观查缺损的大小、形态、周边结构、心腔的大小等。术中根据TTE及造影结果,选择合适的国产封堵器封堵。术后2 d、6个月、≥12月行TTE检查随访观察封堵效果。所有患者完成≥12月的随访,其中178(58.9%)例完成≥3年随访。结果(1)术前TTE,pmVSD左室面大小(10.7±4.6,2.5~26)mm,右室面主孔大小(3.3±1.5,1.5~11)mm;检出漏斗型121(40.1%)例、囊袋多孔型134(44.3%)例、囊袋单孔型39(12.9%)例、窗型8(2.6%)例;检出右冠瓣、无冠瓣脱垂分别为17(5.6%)例、12(3.9%)例,三尖瓣腱索附着异常34(11.3%)例,其中前瓣附着点距缺损边缘无距离11例(3.6%);左房、左室明显增大116(38.4%)例;(2)所有患者均成功封堵,所用封堵器腰部直径(7.3±3.4)mm。(3)随访结果:术后2 d残余分流31(10.3%)例,术后6个月减少至9(3.0%)例,术后(1~3)年有7(2.3%)例残余分流,术后≥3年有4(2.2%,n=178)例。所有患者术后新发主动脉瓣返流11例,均为少量,中远期随访无变化;2例患者TR术后由术前少量增加为中量返流,随访1年以上无明显增加,心腔大小正常。术后第二天,93(30.7%)例患者心腔大小回缩正常,术后6个月所有患者心腔大小均回缩至正常。结论TTE在pmVSD的介入治疗及中远期随访中具有重要的临床应用价值;经导管pmVSD封堵术安全有效,中远期随访结果良好。AIM To evaluate the application value of transthoracic echocardiography(TTE)in interventional treatment and mid-long-term follow-up of perimembranous ventricular septal defect(pmVSD).METHODS A total of 302 patients were diagnosed with pmVSD using TTE,including 129(42.7%)males and 173(57.3%)females,with an average age of(19±16)years.The size of the heart cavity,size,shape and peripheral structure of the defect were observed by multi-view TTE before operation.A suitable domestic occluder was selected according to the results of TTE before operation and angiography during the operation.Follow-up was performed on the second day,6 months and≥12 months after the operation using TTE to observe the closure effect.All patients completed a follow-up of more than 12 months,and 178(58.9%)patients completed a follow-up of more than 3 years.RESULTS TTE identified that pmVSD left ventricular surface size defect was 10.7±4.6(2.5~26)mm and right ventricular surface size of the main hole 3.3±1.5(1.5~11)mm before operation.TTE detected 121(40.1%)cases of funnel type,134(44.3%)cases of capsular porous type,39(12.9%)cases of capsular single-hole type and 8(2.6%)cases of window type.There were 17(5.6%)cases of right coronary valve prolapsed,12(3.9%)cases of non coronary valve prolapsed and 34(11.3%)cases of abnormal attachment of tricuspid chordae tendineae.There were 34(11.3%)cases with abnormal tricuspid chordal attachment and 11 cases(3.6%)had a distance of 0 mm from the anterior valve attachment point to the edge of the defect.There were 116 cases(38.4%)with enlarged left atrium and ventricle.All patients were successfully occluded and the waist diameters of the occluder used were(7.3±3)4 mm.After operation,there were 31(10.3%)cases of residual shunt on the second day,which decreased to 9(3.0%)cases at 6 months,7(2.3%)cases in 1~3 years and 4(2.2%,n=178)cases≥3 years.Eleven cases had new onset of aortic regurgitation after operation,all of which were small and there was no change in the medium and long-term follow-up.Two p
分 类 号:R541.1[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...