基于高压直流输电线路分布参数模型的模态电流差动保护算法  被引量:16

Modal current differential protection method based on distributed parameter model of an HVDC transmission line

在线阅读下载全文

作  者:邵庆祝 赵晓东 赵创业 平夏 SHAO Qingzhu;ZHAO Xiaodong;ZHAO Chuangye;PING Xia(State Grid Anhui Electric Power Co.,Ltd.,Hefei 230000,China;Suzhou Power Supply Company,State Grid Anhui Electric Power Co.,Ltd.,Suzhou 234000,China;Huaibei Power Supply Company,State Grid Anhui Electric Power Co.,Ltd.,Huaibei 235000,China;Huainan Power Supply Company,State Grid Anhui Electric Power Co.,Ltd.,Huainan 232000,China)

机构地区:[1]国网安徽省电力有限公司,安徽合肥230000 [2]国网安徽省电力有限公司宿州供电公司,安徽宿州234000 [3]国网安徽省电力有限公司淮北供电公司,安徽淮北235000 [4]国网安徽省电力有限公司淮南供电公司,安徽淮南232000

出  处:《电力系统保护与控制》2021年第22期171-179,共9页Power System Protection and Control

基  金:国家重点研发计划项目资助(2016YFB0900600)。

摘  要:高压直流输电传输线分布电容电流会造成电流差动保护无法立即区分区内外故障,为避免保护误动作需要增加保护时间延迟和阈值,大大降低了电流差动保护的动作速度和灵敏性。为了使电流差动保护不受传输线分布电容电流影响,在基于传输线分布参数模型上考虑了正负极线路耦合特性,提出了适用于高压直流输电线路的模态电流差动保护算法。该算法以共模补偿电流作为故障识别依据,以差模补偿电流作为故障选极依据。该模态电流差动保护算法在故障期间可以进行故障选区和故障判极,且灵敏度高、动作速度快。最后通过PSCAD/EMTDC仿真验证了该保护方法的可行性和有效性。The distribution capacitor current of a high voltage DC transmission line will cause the current differential protection to fail to distinguish between faults within and outside the zone immediately.In order to avoid the incorrect trip of protection,the time delay and threshold need to be increased.This greatly reduces the action speed and sensitivity of current differential protection.In order not to be influenced by capacitor current of transmission line,this paper considers the coupling characteristics of positive and negative lines on the transmission line distribution parameter model,and puts forward a new mode current differential protection algorithm for a HVDC transmission line.The algorithm uses common mode compensation current as the fault identification basis and differential mode compensation current as the fault pole selection basis.This mode current differential protection can select fault zone and distinguish fault pole during the fault,with high sensitivity and high speed of movement.Finally,the feasibility and effectiveness of this protection method are verified by PSCAD/EMTDC simulation.

关 键 词:高压直流输电 差动保护 分布参数模型 模态电流 耦合特性 

分 类 号:TM721.1[电气工程—电力系统及自动化] TM773

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象