不同类型器械处理过程中对消毒供应中心空气质量的影响研究  被引量:7

The effect of treatment process of different types of medical devices on the air quality of CSSD

在线阅读下载全文

作  者:唐媛[1] 程燕妙 徐一 李纯纯 陈皑皑 陈燕燕 TANG Yuan;CHEN Yan-miao;XU Yi;LI Chun-chun;CHEN Ai-ai;CHEN Yan-yan(The Affiliated Ningbo Eye Hospital of Wenzhou Medical University,Ningbo Zhejiang 315000;Eye Hospital,Wenzhou Medical University,China)

机构地区:[1]温州医科大学附属宁波市眼科医院,浙江宁波315000 [2]温州医科大学附属眼视光医院

出  处:《中国消毒学杂志》2021年第11期807-809,813,共4页Chinese Journal of Disinfection

摘  要:目的研究不同类型医疗器械处理过程中对医院消毒供应中心(CSSD)空气质量的影响,并提出防控建议。方法采用平板沉降法和仪器法,对某医院CSSD处理不同器械过程中产生的颗粒物和沉降菌浓度进行监测与评价。结果使用后医疗器械再处理过程中在CSSD去污区空气中颗粒物和沉降菌都会随之增加。在每日清洗工作结束后,空气中沉降菌数多为1~2 cfu/(皿·5 min),最高为6 cfu/(皿·5 min)。结论使用后医疗器械再处理过程会使处理区域空气中颗粒物和细菌数增加,以管腔器械和粗器械处理过程中产生的颗粒物较多。Objective To study the effect of treatment process of different types of medical devices on the air quality of central sterile supply department(CSSD),and to propose prevention and control recommendations.Methods The dish sedimentation method and instrument method were used to monitor and evaluate the concentration of particulate matter and sedimentary bacteria produced in the reprocessing of different medical devices in CSSD of a hospital.Results The particulate matter and sedimentary bacteria in the air of decontamination zone in the CSSD would increase during the reprocessing of medical devices after use.After the daily cleaning work,the number of sedimentary bacteria in the air was mostly 1 to 2 cfu/dish·5 min,and the highest was 6 cfu/dish·5 min.Conclusion The reprocessing of medical devices after use will increase the number of particulate matter and bacteria in the air of processing area,and more particulate matters will be generated during the processing of lumen devices and coarse devices.

关 键 词:消毒供应中心 医疗器械 再处理 空气颗粒物 沉降菌 

分 类 号:R184[医药卫生—流行病学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象