作 者:杨宝路 张京[1] 周强[1] 拓飞[1] YANG Baolu;ZHANG Jing;ZHOU Qiang;TUO Fei(Key Laboratory of Radiological Protection and Nuclear Emergency,National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention,Beijing 100088 China)
机构地区:[1]中国疾病预防控制中心辐射防护与核安全医学所,辐射防护与核应急中国疾病预防控制中心重点实验室,北京100088
出 处:《中国辐射卫生》2021年第5期564-567,共4页Chinese Journal of Radiological Health
基 金:国家自然科学基金项目(21806156)。
摘 要:目的研究土壤样品过筛粒径和平衡时间对测量放射性核素的影响,提高γ能谱仪测量土壤样品中放射性核素比活度的准确性。方法将采集的土壤样品干燥后分成4份,分别经过2.0 mm、1.0 mm、0.5mm和0.25 mm过筛粒径处理后装入样品盒中密封,然后分别在密封0、4、8、12、16、21、25和29 d后,使用高纯锗γ能谱仪测量土壤中^(226)Ra、^(210)Pb、^(228)Ra、^(40)K和^(137)Cs的比活度并进行比较。结果不同平衡时间间隔测量的土壤样品中^(226)Ra、^(210)Pb和^(228)Ra比活度的变异系数范围为0.9%~4.3%,不同过筛粒径土壤样品中^(226)Ra、^(210)Pb、^(228)Ra、^(40)K和^(137)Cs的比活度的变异系数范围为3.7%~14.1%。结论用γ能谱仪测量土壤中放射性核素的比活度时,须考虑过筛粒径对测量结果的影响,且其影响程度高于平衡时间。研究结果在提高利用γ能谱仪准确测量土壤样品中放射性核素比活度方面具有重要意义。Objective The effect of sieved particle size and equilibration time of soil samples on the measurement of radionuclides was studied to improve the accuracy of the specific activity of radionuclides in soil samples measured by gamma spectrometer.Methods The collected soil samples were dried and divided into four parts.After sieved with width of the mesh 2.0 mm,1.0 mm,0.5 mm and 0.25 mm respectively,they were filled into sample containers and sealed.The activity concentrations of ^(226)Ra,^(210)Pb,^(228)Ra,^(40)K and ^(137)Cs in different sieved soil samples were then measured at the sealed interval of 0,4,8,12,16,21,25 and 29 days by HPGe gamma-ray spectrometry respectively.Results The coefficients of variation ofthe specific activities of ^(226)Ra,^(210)Pb,and ^(228)Ra in soil samples measured at different equilibration intervals range from 0.9%to4.3%.The coefficients of variation of the specific activities of ^(226)Ra,^(210)Pb,^(228)Ra,^(40)K and ^(137)Cs in soil samples with different sieved particle sizes range from 3.7%to 14.1%.Conclusion When the specific activities of radionuclides are determined by gamma-ray spectrometer,the effect of the sieved particle size on the measurement result must be considered,and its impact is higher than the equilibration time.This study is very useful for improving the accuracy of the determination of radionuclides in soil sample using gamma-ray spectrometer.
分 类 号:R144[医药卫生—公共卫生与预防医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145