摘  要:In this study,the influence of the position of the rotor iron bridge on the DC-winding-induced voltage pulsation in a partitioned stator wound field switched flux machine is investigated.Analytical and finite element(FE)analyses show that both the open-circuit and on-load DC-winding-induced voltages can be minimized by positioning the rotor iron bridge adjacent to the inner air gap closer to the DC winding.This is due to a smoother inner air-gap magnetic reluctance while maintaining the average electromagnetic torque at 92.59%of the maximum value.The analyzed machine with the rotor iron bridge adjacent to the inner air gap is prototyped,and the experimental results validate the analytical and FE results.