检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:莎日娜[1] 张冬婕 赵志刚[2] 梅升辉[2] SHA Ri-na;ZHANG Dong-jie;ZHAO Zhi-gang;MEI Sheng-hui(Department of Clinical Pharmacy,Second Affiliated Hospital,Inner Mongolia Medical University,Inner Mongolia Hohhot 010030,China;Department of Pharmacy,Beijing Tiantan Hospital,Capital Medical University,Beijing 100070,China)
机构地区:[1]内蒙古医科大学第二附属医院临床药学管理部,内蒙古呼和浩特010030 [2]首都医科大学附属北京天坛医院药学部,北京100070
出 处:《中国医院药学杂志》2021年第23期2410-2415,共6页Chinese Journal of Hospital Pharmacy
基 金:北京市优秀人才青年骨干项目(编号:2018000021469G238);北京市医管局扬帆计划(编号:ZYLX201827)。
摘 要:目的:评价超高效液相色谱-串联质谱(UHPLC-MS/MS)测定人尿液中甲氨蝶呤浓度的不确定度。方法:通过考察测定方法,分析实验过程中的不确定度来源,包括对照品称量、标准溶液配制和样品制备、回收率及基质效应、校正曲线拟合、仪器的精密性、实验温度和对照品纯度等,然后逐一评定并计算合成不确定度和扩展不确定度。结果:置信概率P为95%时,人尿液中甲氨蝶呤低浓度0.06μmol·L^(-1)和高浓度3μmol·L^(-1)质控样品的扩展不确定度分别为0.0065μmol·L^(-1)和0.20μmol·L^(-1)。结论:根据不确定度的大小及来源,改良测定方法,提高分析准确性。UHPLC-MS/MS法测定人尿液中甲氨蝶呤浓度的不确定度在低浓度时主要由曲线拟合、生物样品配制和标准液配制、回收率及基质效应引入;高浓度的不确定度主要由生物样品配制和标准液配制、回收率引入。OBJECTIVE To evaluate the uncertainty for methotrexate analysis by ultra high performance liquid chromatograph-tandem mass spectrometry(UHPLC-MS/MS)in human urine.METHODS By examining the process of method,the potential sources of methodological uncertainty were analyzed,including weighing of reference substances,preparation of standard solution and sample,recovery rate,matrix effect,fitting of calibration curve,instrumental precision,experimental temperature and purity,etc.The uncertainty of each source component was evaluated to calculate combined uncertainty and expanded uncertainty.RESULTS With a confidence probability of 95%,the expanded uncertainty of methotrexate at low(0.06μmol·L^(-1))and high(3μmol·L^(-1))levels were 0.0065 and 0.20μmol·L^(-1) respectively.CONCLUSION The level of each uncertainty component is examined for improving the analytical method and its accuracy.The uncertainty of this UHPLC-MS/MS method is mostly caused by curve fitting,sample and solution preparation,recovery and matrix effect at a low level.At a high level,uncertainty is largely caused by preparing sample and working solutions and recovery rate.
关 键 词:超高效液相色谱-串联质谱 甲氨蝶呤 尿液 不确定度
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15