检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:宋安东 韩志业 李卫国 SONG Andong;HAN Zhiye;LI Weiguo(Technology Center of CRRC Datong Co.,Ltd.,Datong 037038,China)
机构地区:[1]中车大同电力机车有限公司技术中心,山西大同037038
出 处:《铁道机车与动车》2021年第11期30-32,I0002,共4页Railway Locomotive and Motor Car
摘 要:分析了主变压器原边短路、空载投入励磁涌流和变压器牵引绕组短路故障可能产生的瞬态冲击电流和稳态电流,在主变压器启动空载和带载稳态运行工况下,从稳态保护电流和瞬态保护电流多个角度对主变压器绕组短路故障状态提出相应保护策略,最后以某车型设计运行数据进行保护阈值计算进行验证。The paper analyzes the transient impulse current and steady-state current which may be caused by faults of short-circuit in main transformer primary side,no-load inrush current and the traction winding short-circuit in the transformer. From aspects of steady-state protection current and transient-state protection, the corresponding protection strategies are proposed for the short-circuit fault state of the main transformer windings under the starting no-load and load operation conditions.Finally, the protection threshold is calculated and verified on the basis of the design and operation data of a certain type locomotive.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222