作 者:易延伟 YI Yanwei(China Telecom Corporation Ltd Fuzhou Branch,Fuzhou 350000,China)
机构地区:[1]中国电信股份有限公司福州分公司,福建福州350000
出 处:《通信电源技术》2021年第13期53-54,57,共3页Telecom Power Technology
摘 要:现有环境下,市电的供电可靠性在不断提高,市电因故障中断的修复时长也在逐步缩短。在短时间内市电中断的情况下,延时启动发电机组对机房提供电力保障也是一种降低运营商燃油成本的方法。机房内蓄电池续航能力充足并且温度环境在允许范围内的情况下,发电机组可以暂时不开启。综合评估蓄电池续航能力与机房温度,并分析发电机组延时启动的可行性。In the current environment,the reliability of mains power supply is improving,and the repair period for mains faults is shortening.In the case of a short period of mains interruption,the delayed start of the generator set to provide power to the equipment room is also a way to reduce the operator’s fuel cost.If the battery life in the equipment room is sufficient and the temperature is within the allowable range,the generator set can be temporarily disabled.In this paper,the feasibility of delayed start of generator set is analyzed based on the comprehensive evaluation of battery endurance and machine room temperature.
分 类 号:TP3[自动化与计算机技术—计算机科学与技术]