钢轨与转辙机固定钢板间的绝缘垫击穿故障分析  

Analysis of Fault of Breakdown of Insulation Pad between Rail and Steel Plates for Fixing of Switch Machine

在线阅读下载全文

作  者:杨尚霄 刘家材 曹晓斌[3] YANG Shangxiao;LIU Jiacai;CAO Xiaobin

机构地区:[1]神华包神铁路有限责任公司 [2]国网四川省电力公司泸州供电公司 [3]西南交通大学电气工程学院

出  处:《电气化铁道》2021年第6期108-110,共3页Electric Railway

摘  要:钢轨与转辙机固定钢板间的绝缘垫击穿可能导致漏电事故发生,甚至可能引发其他事故。本文对电气化铁路常见的钢轨与转辙机固定钢板间的绝缘垫击穿事故进行分析,基于串联分压原理设计了一套转辙机固定钢板接地电阻的测量方法,通过分析实测数据排查出绝缘垫击穿的原因,并提出绝缘垫击穿隐患的防范措施。The breakdown of the insulating pad between the rail and the fixing steel plate of the switch machine may lead to electric leakage accidents,or even other accidents.The paper analyzes the common insulation pad breakdown accidents between rail and fixing steel plate of switch machine in electrified railway,designs a set of measurement method of earthing resistance of fixing steel plate of switch machine based on the principle of series partial voltage,finds out the causes of insulation pad breakdown by analyzing the measured data,and puts forward the preventive measures for the hidden dangers of insulation pad breakdown.

关 键 词:绝缘垫 击穿事故 接地电阻测量 防范措施 

分 类 号:U226.5[交通运输工程—道路与铁道工程]

 