Effect of fluoroscopy frame rate on radiation exposure and in-hospital outcomes in cardiovascular implantable electronic device implantation procedures  

在线阅读下载全文

作  者:Muzaffar Ali Bharatraj Banavalikar Khalil Kanjwal Milan Kumar Ghadei Anju Kottayan Deepak Padmanabhan Jayaprakash Shenthar 

机构地区:[1]Department of Cardiac Electrophysiology,Sri Jayadeva Institute of Cardiovascular Sciences and Research,Bangalore,India [2]Department of Cardiology,Sher-i-Kashmir Institute of Medical Sciences,Srinagar,Kashmir,India [3]Department of Cardiology,Division of Clinical Cardiac Electrophysiology,McLaren Greater Lansing Hospital,Michigan,USA

出  处:《Radiation Medicine and Protection》2021年第4期176-180,共5页放射医学与防护(英文)

摘  要:Objective:To assess the radiation exposure in cardiovascular implantable electronic device(CIED)implantation procedures,the effect of fluoroscopy frame rate on various radiation exposure indices,and in-hospital outcomes.Methods:Data of CIED implantation procedures from September 2015 to December 2019 of all the CIED implantation procedures performed at our institute were retrospectively analyzed.The procedural data were divided into two groups:a)pre-group:procedures that were performed under fluoroscopy frame rate of 7.5 frames per second(fps);b)post-group:procedures that were performed under fluoroscopy frame rate of 3.75 fps.We compared procedure time,fluoroscopy time,Kerma air product,effective dose,and in-hospital outcomes between the two groups.Results:A total of 2,225 procedures were included in the analysis with mean age of(62±15)years.The procedures consisted of the implantation of single-chamber(n=1,436),double chamber(n=656),and biventricular devices(n=133).Procedure time and radiation indices showed a significant reduction over the study period(P<0.001).Reduction in the fluoroscopy frame rate was associated with a significant reduction in radiation exposure indices(P<0.001).In-hospital outcomes did not differ between the two groups.Conclusions:Reduction in the fluoroscopy frame rate from 7.5 to 3.75 fps significantly decreased the radiation exposure in CIED implantation procedures.A framerate lower than 3.75 fps should be the default setting during such procedures.

关 键 词:Cardiovascular implantable electronic devices Effective dose Fluoroscopy time Kerma air product PACEMAKERS Radiation exposure 

分 类 号:R54[医药卫生—心血管疾病]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象