检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:林文风 张小红 张国文 孙立琴 程宝珍 虞海娟 LIN Wenfeng;ZHANG Xiaohong;ZHANG Guowen;SUN Liqin;CHENG Baozhen;YU Haijuan
机构地区:[1]中国科学技术大学附属第一医院急诊医学科,合肥市230001 [2]中国科学技术大学附属第一医院门诊部办公室,合肥市230001
出 处:《中华护理杂志》2021年第12期1898-1900,共3页Chinese Journal of Nursing
基 金:安徽省高等学校省级质量工程项目(2020jyxm2309)。
摘 要:目的自制雾化器固定支架,并探讨其临床应用效果。方法设计的雾化器固定支架包括底座、连接杆、万向软管和雾化杯固定部4个部分。便利选取2020年7月—12月合肥市某三级甲等医院急诊病房收治的63例患者作为试验组,选取2020年1月—6月收治的63例患者作为对照组。试验组采用自行设计的雾化器固定支架辅助进行雾化,对照组采用手持雾化器的方式进行雾化。比较两组雾化时间、雾化中断次数、雾化舒适率。结果试验组雾化时间为(23.05±2.86)min,对照组为(16.46±2.31)min,两组比较,差异具有统计学意义(P<0.001);试验组雾化中断次数为(0.86±0.47)次,对照组为(1.77±0.57)次,两组比较,差异具有统计学意义(P=0.013);试验组雾化舒适率为92.06%,对照组为76.19%,两组比较,差异具有统计学意义(P=0.031)。结论雾化器固定支架使用方便,可减少雾化中断次数,延长雾化时间,提高患者的雾化舒适度,有利于提升患者对雾化治疗的依从性。Objective This study explored the application effects of a self-designed atomizer fixing bracket in the atomization process of patients.Methods The self-designed atomizer fixing bracket includes 4 parts with a base,a connecting pipe,a universal hose and a fixing part of the atomizer cup.63 patients in the emergency ward of a tertiary first-class hospital in Hefei from January to June 2020 were selected as the control group;63 patients from July to December 2020 were in the test group.Patients of the test group used a self-designed atomizer fixing bracket to assist atomization process,while patients of the control group used conventional standard atomization methods for atomization treatment.The comfort of atomization,the atomization time and the number of atomization interruptions were observed in 2 groups.Results The atomization time of the test group were(23.05±2.86)min,and the atomization time of the control group were(16.46±2.31)min with statistically significant differences between the 2 groups(P<0.001).The numbers of atomization interruptions in the test group were(0.86±0.47)times,while the numbers of atomization interruptions in the control group were(1.77±0.57)times,and the difference between the 2 groups was statistically significant(P=0.013).The comfort rate of atomization in the test group was 92.06%,and the control group was 76.19%.The difference between the 2 groups was statistically significant(P=0.031).Conclusion The atomizer fixing bracket was convenient to use,which can help to improve the comfort of atomization of patients,reduce the number of interruptions of atomization,extend the time of atomization,and help improving the compliance of patients with atomization therapy.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.133.123.140