检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘昊宇[1] 刘崇茹[1] 蒋思雯 LIU Haoyu;LIU Chongru;JIANG Siwen(State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources,North China Electric Power University,Beijing 102206,China)
机构地区:[1]华北电力大学新能源电力系统国家重点实验室,北京102206
出 处:《电力自动化设备》2022年第1期164-170,共7页Electric Power Automation Equipment
基 金:国家电网公司科技项目(2019-579)。
摘 要:附加频率控制利用基于电压源型换流器的多端柔性直流输电(VSC-MTDC)系统直流电压变化传递故障交流系统频率变动,促使非故障交流系统所连电压源型换流器(VSC)消纳不平衡功率参与频率调节。然而固定下垂系数灵活性不足,在不平衡功率分配时忽略VSC实时运行状态与交流网络稳定性,无法保证系统参与频率调整的同时安全稳定运行。通过研究频率变动造成的功率不平衡量分配和直流电压下垂系数的定量关系,提出一种计及系统运行状态的VSC-MTDC动态附加频率控制策略,将VSC功率裕度和交流网络频率变化量引入下垂系数,动态调整不平衡功率的分配比例。仿真结果证明,应用动态附加频率控制进行频率调节后,频率偏差较小的交流网络在所连VSC功率裕度较大时能承担更多不平衡功率,而频率偏差较大的交流网络所连换流站不平衡功率配比下降,VSC-MTDC系统安全稳定运行水平得到显著改善。The additional frequency control utilizes the DC voltage variation of VSC-MTDC(Voltage Source Converter based Multi-Terminal Direct Current)system to represent the frequency variation of the AC sys⁃tem with faults.In this way,the VSC connected to non-fault AC system is assigned to accommodate the unbalanced power and participate in frequency regulation.However,the flexibility of the DC voltage droop control with constant coefficients is relatively insufficient.The real-time operation status of VSC and the stability of AC system are neglected when allocating the unbalanced power among all remaining non-fault AC systems,which cannot guarantee that the operation of VSC-MTDC is secure and stable.By analyzing the quantitative relationship between the unbalanced power distribution caused by the frequency variation and DC voltage droop coefficient,a dynamic additional frequency control strategy of VSC-MTDC is proposed.The frequency deviation of the AC systems and the power margin of the VSCs are introduced into the DC voltage droop coefficient to dynamically adjust the unbalanced power distribution ratio.The simulative results show that,by adopting the proposed strategy,the AC system with smaller frequency deviation can accommo⁃date higher level of unbalanced power when the connected VSC power margin is large,while the unbalanced power distribution ratio of VSCs connected to the AC systems with larger frequency deviation is reduced dramatically.Therefore,the proposed control strategy effectively improves the secure operating ability of VSC-MTDC system.
关 键 词:基于电压源型换流器的多端柔性直流输电 动态附加频率控制 动态直流电压下垂系数 频率偏差量 功率裕度
分 类 号:TM721.1[电气工程—电力系统及自动化] TM761
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222