中能质子注量率测量  被引量:1

Measurement of medium-energy proton flux

在线阅读下载全文

作  者:张艳文 郭刚[1] 肖舒颜 殷倩 杨新宇 Zhang Yan-Wen;Guo Gang;Xiao Shu-Yan;Yin Qian;Yang Xin-Yu(National Innovation Center of Radiation Application,Department of Nuclear Physics,China Institute of Atomic Energy,Beijing 102413,China)

机构地区:[1]中国原子能科学研究院核物理研究所,国防科技工业抗辐照应用技术创新中心,北京102413

出  处:《物理学报》2022年第1期66-73,共8页Acta Physica Sinica

基  金:国家自然科学基金(批准号:11805281)资助的课题。

摘  要:质子是太空辐射环境中的主要粒子成分,随着半导体工艺向着小尺寸高集成度方向不断发展,质子单粒子效应不容忽视.通过加速器模拟空间辐射进行地面实验是评价质子单粒子效应最重要的手段,质子注量率的准确测量是器件考核评估过程中最关键的环节.本文基于原子能院100MeV质子单粒子效应辐照装置,突破了宽量程中能质子注量率测量技术,开发了法拉第筒、塑料闪烁体探测器和二次电子发射监督器等探测工具,可以对束流进行宽量程范围准确测量,解决了质子注量率在106—107 p·cm^(-2)·s^(-1)范围内难以测量的关键难题,并进行了注量率不确定度的分析研究,同一注量率下法拉第筒和塑料闪烁体探测器的实验测量误差与理论分析误差相符.对中能质子注量率测量达到了国际同类装置水平.该研究建立的中能质子注量率测量系统和不确定度分析方法,为准确评估元器件辐射效应奠定了基础.Proton is the main particle component in the space radiation environment.The proton single event effect cannot be ignored with the continuous development of semiconductor technology.Accelerator simulation is the most important method to evaluate the single event effect caused by proton radiation,and the accurate measurement of proton flux is the most critical aspect in the device evaluation process.The research is based on the 100 MeV proton single-event irradiation device of the Atomic Energy Institute,which breaks through the wide-range mid-energy proton fluence rate measurement technology.The detection tools are developed such as Faraday cup,plastic scintillator detectors and secondary electron emission monitors,which can be used for measuring the proton beam current in a wide range.Faraday cup and plastic scintillator detector can be used for measuring the high flux proton and the low flux proton,respectively.Secondary electron emission monitor can be used for conducting the online real-time measurement.The proton fluxes in a range of 106-107 p·cm^(-2)·s^(-1) are measured by using two separate detectors.The analysis of the fluence rate uncertainty is carried out.The uncertainty of measurement results mainly include three aspects:measurement method,measuring instrument and equipment,and repeatability of multiple measurement results.Here in this work,the Faraday cup is taken for example to analyze the uncertainty sources in the proton flux measurement.The measurement methods include the calculation of the collection efficiency of the Faraday cup(collection efficiency+escape rate=1)and the calculation method of flux(flux=current/collection area).For the measuring instruments and equipment,mainly including 6517 A and other electronic devices,their errors are determined by the accuracies of the instruments themselves.Repeatability of multiple measurement results mainly from the error caused by the instability of the accelerator beam output,the error caused by randomness of multiple measurement results,and the er

关 键 词:中能质子 注量率测量 束流探测器 不确定度分析 

分 类 号:TL50[核科学技术—核技术及应用] TL81

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象