检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘振明 Liu Zhen-ming
机构地区:[1]国能亿利能源有限责任公司电厂,内蒙古鄂尔多斯014300
出 处:《电力系统装备》2021年第24期65-66,共2页Electric Power System Equipment
摘 要:某电厂机组配汽方式在额定负荷下能够到达设计效率,但低负荷时,高调门存在较大的节流损失,且下进汽方式存在气流激振现象导致轴系失稳。机组参与调峰,50%~80%负荷运行,为提高机组的经济性和安全性,对高调门进行了综合配汽优化,效果显著。The steam distribution mode of a power plant unit can reach the design efficiency under rated load,but at low load,there is a large throttling loss of high control valve;And the lower steam inlet mode has the phenomenon of air flow excitation,which leads to the instability of the shaft system.The unit participates in peak shaving and operates at 50%-80%load.In order to improve the economy and safety of the unit,the high-pressure regulating valve is comprehensively optimized,and the effect is remarkable.
分 类 号:TM623[电气工程—电力系统及自动化]