检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Sheng Shu Jie An Pengfei Chen Di Liu Ziming Wang Chengyu Li Shuangzhe Zhang Yuan Liu Jianzhe Luo Lulu Zu Wei Tang Zhong Lin Wang
机构地区:[1]CAS Center for Excellence in Nanoscience,Beijing Key Laboratory of Micro-Nano Energy and Sensor,Beijing Institute of Nanoenergy and Nanosystems,Chinese Academy of Sciences,Beijing 100083,China [2]School of Nanoscience and Technology,University of Chinese Academy of Sciences,Beijing 100049,China [3]Center on Nanoenergy Research,School of Physical Science&Technology,Guangxi University,Nanning 530004,China [4]Institute of Applied Nanotechnology,Jiaxing,Zhejiang 314031,China [5]CUSPEA Institute of Technology,Wenzhou,Zhejiang 325024,China [6]School of Materials Science and Engineering,Georgia Institute of Technology,Atlanta,GA 30332-0245,USA
出 处:《Research》2021年第1期814-825,共12页研究(英文)
基 金:supported by the National Key R&D Project from the Minister of Science and Technology(2016YFA0202704);Youth Innovation Promotion Associ-ation CAS,Beijing Municipal Science&Technology Commission(Z171100000317001,Z171100002017017,and Y3993113DF);National Natural Science Foundation of China(Grant Nos.51605033,51432005,5151101243,and 51561145021).
摘 要:Sensors capable of monitoring dynamic mechanics of tendons throughout a body in real time could bring systematic information about a human body’s physical condition,which is beneficial for avoiding muscle injury,checking hereditary muscle atrophy,and so on.However,the development of such sensors has been hindered by the requirement of superior portability,high resolution,and superb conformability.Here,we present a wearable and stretchable bioelectronic patch for detecting tendon activities.It is made up of a piezoelectric material,systematically optimized from architectures and mechanics,and exhibits a high resolution of 5:8×10^(−5)N with a linearity parameter of R^(2)=0:999.Additionally,a tendon real-time monitoring and healthcare system is established by integrating the patch with a micro controller unit(MCU),which is able to process collected data and deliver feedback for exercise evaluation.Specifically,through the patch on the ankle,we measured the maximum force on the Achilles tendon during jumping which is about 16312 N,which is much higher than that during normal walking(3208 N)and running(5909 N).This work not only provides a strategy for facile monitoring of the variation of the tendon throughout the body but also throws light on the profound comprehension of human activities.
关 键 词:PATCH integrating THROUGHOUT
分 类 号:TP212[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.186