检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:仲继泽 邱昌林[1] 沈渡[1] 孙启滨 杜堃[1] 徐自力[2] ZHONG Jize;QIU Changlin;SHEN Du;SUN Qibin;DU Kun;XU Zili(National Key Laboratory on Ship Vibration & Noise, China Ship Development and Design Center, Wuhan 430064, China;State Key Laboratory for Strength and Vibration of Mechanical Structures, Xi’an Jiaotong University, Xi’an 710049, China)
机构地区:[1]中国舰船研究设计中心船舶振动噪声重点实验室,武汉430064 [2]西安交通大学机械结构强度与振动国家重点实验室,西安710049
出 处:《西安交通大学学报》2022年第1期79-84,共6页Journal of Xi'an Jiaotong University
基 金:国家自然科学基金资助项目(51675406)。
摘 要:为控制海水冷却系统通海口产生的辐射噪声,考虑管路及管路附件的弹性影响,建立了简化的通海系统流噪声传递-辐射的仿真模型;从避免管路流噪声传递损失的角度,提出了基于总传递损失的管路系统声传递-辐射特性的评价方法;借助商业软件计算了不同管路附件影响下的管路声传递-辐射的总传递损失,给出了管路附件对管路声学总传递损失的影响规律。计算结果表明,与无管路附件的直管路相比,换热器可以使总传递损失提高94.9 dB,挠性接管可提高33 dB,截止止回阀可提高28.5 dB,相比之下,滤器、变径管、弯头对总传递损失的提升均小于10 dB,蝶阀仅可提高1.5 dB。通过研究发现,管路附件可以提高对通海系统辐射噪声的控制效果。实际的海水冷却系统的管路附件集中在系统出口管路,使得出口管路附件多于进口管路,导致进口管路辐射噪声控制不足。增加进口管路上的管路附件可提高系统辐射噪声的控制效果。To control the radiation noise at the open end of pipe for a seawater cooling system,a simplified numerical model is established for the acoustic transfer-radiation of hydrodynamic noise throughout pipelines in the seawater cooling system in consideration of elasticity of pipe and pipe fittings.From the perspective of hydrodynamic noise transmission loss through pipes and pipe fittings,an evaluation methodology for the acoustic transfer-radiation characteristic through pipelines is proposed based on the total acoustic transmission loss.The total acoustic transmission loss of a pipe system with different pipe fittings is calculated using a commercial software of computational acoustics,and the effect of pipe fittings on acoustic transfer-radiation characteristic is revealed.Computation results show that the total transmission loss is increased by about 94.9 dB by the heat exchanger,33 dB by the flexible tube,and 28.5 dB by the stop check valve,compared with a straight pipe.However,the increment of total transmission loss is below 10 dB by colander,elbow and adapter bonnet,and is only 1.5 dB by butterfly valve.It can be concluded that pipe fittings tend to promote the total transmission loss.Outlet pipe of an actual cooling system usually contains a heat exchanger and more fittings than the inlet pipe,however,the radiation noise of the system in the inlet pipe is not properly controlled.So it is suggested that more pipe fittings be mounted into the inlet pipe to control the radiation noise.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.142.133.182