外墙外保温系统透气性抹面胶浆的研究  

Research on air permeability plastering mortar for external thermal insulation systems

在线阅读下载全文

作  者:赵长才 占飞 郭镜铭 陈岩 ZHAO Zhangcai;ZHAN Fei;GUO Jingming;CHEN Yan(Suzhou Gusu New Building Materials Co.Ltd.,Suzhou 215129,China;Suzhou Xindi Construction Engineering Quality Inspection Co.Ltd.,Suzhou 215121,China)

机构地区:[1]苏州市姑苏新型建材有限公司,江苏苏州215129 [2]苏州新地建设工程质量检测有限公司,江苏苏州215121

出  处:《新型建筑材料》2022年第1期127-131,共5页New Building Materials

摘  要:详细论述了外墙外保温系统透气性抹面胶浆的研制过程,主要由水泥、砂、乳胶粉、膨胀珍珠岩、微沫剂等多种成分组成。测试结果表明,透气性抹面胶浆综合性能符合GB/T 29906—2013和GB/T 30595—2014等标准要求,特别地,其水蒸气透过湿流密度达到1.76 g/(m^(2)·h)(4 mm厚),导热系数为0.1658 W/(m·K),远低于普通抹面胶浆[0.3590 W/(m·K)],综合性能优异。The development process of air permeability plastering mortar for external thermal insulation systems is discussed in detail. It is mainly composed of cement,sand,emulsion powder,expanded perlite,foaming agent and other components. The test results show that the comprehensive performance of air permeability plastering mortar meets the requirements of GB/T 29906 —2013 and GB/T 30595—2014. In particular,the density of water vapor transmission reaches 1.76 g/(m^(2)·h)(4 mm-thick),The thermal conductivity [0.1658 W/(m·K)] is much lower than that of ordinary plastering mortar [0.3590 W/(m·K)],the comprehensive performance is excellent.

关 键 词:抹面胶浆 透气性 保温性 导热系数 

分 类 号:TU551[建筑科学—建筑技术科学]

 