摘 要:搭建20层的全尺寸办公建筑三维模型,通过设置不同窗户面积、窗户位置研究外窗对建筑外立面竖向火蔓延的影响。研究发现窗户面积较大时,火灾竖向蔓延速率更快,室内温度升高更快,采用大的窗墙比更容易加快火灾在建筑外立面的竖向蔓延。在竖直位置上,随着窗户上移,各楼层的引燃时间均增加。A three-dimensional model of a 20 story full-scale office building was built,and the influence of window on the vertical fire spread over the building facade was studied by setting different window area and location.It was found that: When the window area was larger,the vertical spread rate of fire was faster,and the indoor temperature raised faster.The large windowwall ratio accelerated the vertical spread of fire over the building facade.As the window moved upward in the vertical position,the ignition time of each floor increased.