氯压机系统一、二级换热器失效原因分析与应对措施  

Countermeasures and Failure Cause Analysis on the Primary and Secondary Heat Exchangers of Chlorine Compressor System

在线阅读下载全文

作  者:王观东 WANG Guandong(Sino-Pec Group Epoxy Resin Factory of Baling Petrochemical Co.,Ltd.,Yueyang 414014,China)

机构地区:[1]中石化巴陵石油化工有限公司树脂部,湖南岳阳414014

出  处:《机械工程师》2022年第2期62-65,68,共5页Mechanical Engineer

摘  要:针对氯气压缩机系统一、二级换热器腐蚀失效速度过快问题,从生产工艺过程控制、设备结构设计及制造、防腐选择与施工等方面进行分析研究,确认设备腐蚀失效的原理机制,制定针对性的解决方案并实施,有效延长设备服役寿命。In view of the excessively fast corrosion failure rate of the primary and secondary heat exchangers of the chlorine compressor system, this paper analyzes the production process control, equipment structure design and manufacturing, anti-corrosion selection and construction, confirms the principle and mechanism of equipment corrosion failure, and formulates pertinence and implement the solutions to effectively extend the service life of the equipment.

关 键 词:氯气 腐蚀 结垢 制造缺陷 防护 

分 类 号:TQ050.9[化学工程]

 