检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:江红 许城城 陈映淳 赵承宽 李海燕 张秋珍 谢金平 陈松 JIANG Hong;XU Chengcheng;CHEN Yingchun;ZHAO Chengkuan;LI Hai-yan;ZHANG Qiuzhen;XIE Jinping;CHEN Song(Guangzhou Red Cross Hospital,Guangzhou 510220,China;不详)
机构地区:[1]广州市红十字会医院,广州510220 [2]汕头大学医学院,广东汕头515041
出 处:《实用医学杂志》2022年第2期239-242,共4页The Journal of Practical Medicine
基 金:2018年度汕头市第三批医疗卫生科技计划(自筹经费类)项目(编号:汕府科﹝2018﹞121号,180723154011141)。
摘 要:目的观察CT增强扫描中脉冲式预注射生理盐水的方法对预防造影剂外渗的效果。方法将符合入组条件的10 200例CT增强扫描的患者随机分为对照组和研究组,每组5 100例,对照组患者给予传统方法预注射生理盐水,研究组患者给予脉冲式预注射生理盐水,在检查结束后,比较两组患者造影剂外渗发生率,调查患者对CT增强扫描的满意度,在研究时间区间内,记录每2个月中两组内各自发生的医患纠纷频次。结果研究组造影剂外渗发生率较对照组明显下降(P <0.05),研究组患者较对照组在整套检查中表现更高满意度(P <0.05),在本研究期间内研究组内患者与医护人员发生医患纠纷的频次明显减少(P <0.05)。结论脉冲式预注射生理盐水可有效减少CT增强扫描造影剂外渗发生率,提高CT增强扫描检查的满意度,具有重要的临床应用价值。Objective Observe the effect of pulsatile pre-injected physiological saline solutions in enhanced CT scanning to prevent contrast media extravasation. Methods 10 200 patients who meet the enrollment criteria with routine enhanced CT scanning in our hospital were selected for the study. They were randomly divided into into a control group and a research group,with 5100 patients in each group. Thepatients in the control group were given physiological saline solutions with traditional methods and the patients in research group were given physiological saline solutions with pulsatile pre-injection. After the examination,the incidence of contrast media extravasation was compared between the two groups,and the satisfaction with enhanced CT scanning was investigated. The frequency of medical disputes between internal patients and medical staff in the two groups was recorded every 2 months within the study period. Results The incidence of contrast media extravasation in the study group was significantly lower than that in the control group(P < 0.05). The patients in the study group showed higher satisfaction than the control group in the entire set of examinations(P < 0.05). The frequency of medical disputes between internal patients and medical staff was significantly reduced(P < 0.05). Conclusion Pulsatile pre-injection physiological saline solutions can effectively reduce the incidence of contrast media extravasation in enhanced CT scanning and improve patients’ satisfaction with enhanced CT scanning,which has important clinical application value.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.136.159.203