检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马庆玲 杨东 邓延飞 曾莉[2] 林华 田永红 MA Qing-ling;YANG Dong;DENG Yan-fei;ZENG Li;LIN Hua;TIAN Yong-hong(Jianyang Center for Disease Control and Prevention,Jianyang 641400,Sichuran Province,China;Chengdu Center for Disease Control and Prevention,Chengdu 610000.Sichuan Prorince,China)
机构地区:[1]简阳市疾病预防控制中心,四川简阳641400 [2]成都市疾病预防控制中心,成都610000
出 处:《职业卫生与病伤》2022年第1期40-44,共5页Occupational Health and Damage
摘 要:目的分析简阳市2016—2020年疑似预防接种异常反应(adverse event following immuni-zation,AEFI)发生特征,评价预防接种异常反应监测系统运转情况,为AEFI监测工作提供参考依据。方法通过全国AEFI信息管理系统收集简阳市2016—2020年AEFI个案数据,采用描述流行病学的方法进行统计分析。结果2016—2020年简阳市共报告AEFI 622例,报告发生率为46.65/10万剂,简阳市21个乡镇均有AEFI报告,48 h内报告报告率为99.84%,48 h内调查率为98.51%。AEFI报告发生例数≤1岁组占74.60%,接种后0~1 d发生占91.00%,集中发生在5~8月。AEFI分类中一般反应555例,发生率41.63/10万剂;异常反应54例,发生率4.05/10万剂;偶合症13例,发生率0.96/10万剂。AEFI报告发生率居前5位的疫苗分别为DTap-Hib四联疫苗(25.68‰)、23价肺炎球菌疫苗(13.67‰)、百白破(无细胞)疫苗(12.93‰)、含麻疫苗(麻腮风疫苗+麻腮疫苗)(5.46‰)和乙脑减毒活疫苗(3.67‰)。结论2016—2020年简阳市AEFI监测系统运转良好、监测敏感性逐年提高、各类疫苗安全可靠、预防接种服务质量较好,但是AEFI监测报告发生率与实际存在一定偏差,监测数据的敏感性、准确性及监测质量有待进一步提高。Objective To analyze the epidemiological characteristics of adverse events following immunization(AEFI)in Jianyang from 2016 to 2020,to evaluate the operation of AEFI surveillance system,and to provide reference for AEFI monitoring.Methods The AEFI case data of Jianyang City from 2016 to 2020 were collected through the National AEFI Information Management System,and the descriptive epidemiological methods were used for statistical analysis.Results From 2016 to2020,a total of 622 AEFI cases were reported in Jianyang City,with a reported occurrence rate of 46.65/10^(5) doses.AEFI cases were reported in all of the 21 towns of Jianyang City.The reported rate within 48 hours was 99.84%,and the investigation rate within 48 hours was 98.51%.74.60%of AEFI cases were less than 1 year old and 91.00%occurred at 0-1 day after vaccination.Most cases occurred between May and August.There were 555 cases of general reaction(the occurrence rate:41.63/10^(5) doses),54 cases of abnormal reaction(4.05/10^(5) doses)and 13 cases of coupling diseases(0.96/10^(5) doses).The top five vaccines reported with AEFI were DTaP-Hib(25.68‰),23-valent pneumococcal vaccine(13.67‰),DTaP(12.93‰),MMR or MR vaccine(5.46‰)and JEV(3.67‰).Conclusions From 2016 to 2020,the AEFI monitoring system in Jianyang City worked well.The monitoring sensitivity increased year by year.All kinds of vaccines were safe and reliable,and the quality of vaccination service was good.However,there was a certain deviation between the reported occurrence rate of AEFI surveillance and the actual situation.Since,the sensitivity,accuracy and quality of monitoring data need to be further improved.
关 键 词:疑似预防接种异常反应(AEFI) 监测 疫苗
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.20