检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张仁玉 朱发熙 ZHANG Renyu;ZHU Faxi(China Information Consulting&Designing Institute Co.,Ltd.,Nanjing 210019,China)
机构地区:[1]中通服咨询设计研究院有限公司,江苏南京210019
出 处:《通信电源技术》2021年第17期31-35,共5页Telecom Power Technology
摘 要:基于第三路市电和10 kV储能系统,提出一种新的适合在数据中心应用的供电系统架构。该供电架构既能满足数据中心对供电安全可靠性的要求,同时又方便新能源和储能设备的接入。数据中心采用这种供电系统架构,不仅能够利用“峰谷”电价差获得微观经济效益,同时也能帮助电网调峰调频,实现电网“削峰填谷”的宏观收益。Based on the third municipal power supply and 10 kV energy storage system,this paper proposes a new power supply architecture suitable for data center applications.This power supply architecture can not only meet the data center’s requirements for power supply safety and reliability,but also facilitate the access of new energy and energy storage equipment.If the system is promoted and used in data centers,it can not only use the“peak-to-valley price”difference to obtain micro-economic benefits,but also help the power grid to adjust peaks and achieve the macro benefits of“peak-shaving and valley-filling”of the power grid.
分 类 号:TP3[自动化与计算机技术—计算机科学与技术]
正在载入数据...