Design of readout electronics based on peak-holding circuit and multiplexer for a fast neutron spectrometer  被引量:1

在线阅读下载全文

作  者:Liyang Sun Kai Zhuang Xiaoming Wang Fanjian Zeng Heng An Daowu Li Yuxiong Xue Zhiming Zhang Wei Zhou Yingjie Wang Baotong Feng Peilin Wang Xiaohui Li Jiale Cai Teng Tong Fanhui Meng Junguang Zhou Huan Huang Xuanhou Hu Xiubo Qin 

机构地区:[1]Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049,China [2]Beijing Engineering Research Center of Radiographic Techniques and Equipment,Beijing 100049,China [3]School of Nuclear Science and Technology,University of Chinese Academy of Sciences,Beijing 100049,China [4]Lanzhou Institute of Physics,Chinese Academy of Space Technology,Lanzhou 730000,Gansu,China

出  处:《Radiation Detection Technology and Methods》2018年第1期38-48,共11页辐射探测技术与方法(英文)

基  金:This work was supported by the Ministry of Science and Technology of China(2013YQ03062902);CAS pilot strategic science and technology projects(XDA14020502);the National Natural Science Foundation of China(U1332202).

摘  要:Background Fast neutron detection is meaningful in many research fields such as space environment monitoring.A scintillating fiber array model for fast neutron detection was proposed and developed in 1980s.Aerospace applications of the model require electronics in small size.Purpose To design a dedicated electronic system to readout and process the 384-channel signals from scintillating fiber array,and to use the designed system to fabricate a neutron detector for aerospace applications.Methods With the method of nuclear recoil,fast neutron is detected by tracking recoil proton of n–p scatter in scintillating plastic fibers.Using the peak-holding circuits and multiplexers,the system size and power consumption were reduced.Results The detector fabricated with the designed system,had 34 cm×34 cm×27 cm mechanical size,20.4 kg weight,and 30.05W power consumption.Comparing to traditional waveform sampling electronics,the designed electronics was highly integrated and had a small size.The readout electronics also gave a better energy resolution of 39%in neutron detection,while the energy resolution was 43%in previous version.Conclusion In this study,a highly integrated readout electronic system was designed and verified.The detector using the system gave good performance.The designed electronics had potential development in fast neutron detection and other high energy physics detection system.

关 键 词:MULTIPLEXER Peak-holding circuit Readout electronics Fast neutron detection 

分 类 号:O57[理学—粒子物理与原子核物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象