作 者:张春香[1] 刘旭 靳俊玲 申有名[1] 谷标 ZHANG Chunxiang;LIU Xu;JIN Junling;SHEN Youming;GU Biao(Hunan Province Cooperative Innovation Center for the Construction&Development of Dongting Lake Ecological Economic Zone,College of Chemistry and Materials Engineering,Hunan University of Arts and Science,Changde 415000;Key Laboratory of Functional Metal-Organic Compounds of Hunan Province,College of Chemistry and Materials Science,Hengyang Normal University,Hengyang 421008)
机构地区:[1]洞庭湖生态经济区建设与发展协同创新中心,湖南文理学院化学与工程学院,常德415000 [2]功能金属有机化合物湖南省高校重点实验室,衡阳师范学院化学与材料科学学院,衡阳421008
出 处:《分析试验室》2022年第2期130-134,共5页Chinese Journal of Analysis Laboratory
基 金:国家自然科学基金(21907026);湖南省自然科学基金(2019JJ50009);湖南省教育厅资助项目(18B369,20A338);常德市指导性科技计划项目(2020ZD28);湖南文理学院科学研究项目(20YB23)资助。
摘 要:利用二甲基硫代氨基甲酸酯对次氯酸(HOCl)的特异性和吡啶盐的水溶性,以4-羟基异苯并呋喃-1,3-二酮作为原料,设计合成了一种检测HOCl的全水溶性激发态分子内质子转移(ESIPT)荧光探针。由于二甲氨基硫代甲酸酯对羟基的保护,探针分子内的ESIPT作用被阻碍,自身无荧光;当加入HOCl时,HOCl氧化二甲氨基硫代甲酸酯,释放出羟基,分子内出现了ESIPT过程,荧光增强。探针在水溶液中对HOCl的检测线性范围为0~80μmol/L,定量限为94 nmol/L。该探针对HOCl的响应时间为4 min,Stokes位移为113 nm,检测限为94 nmol/L。方法可用于水样和活细胞中HOCl的检测。A full water-soluble excited intramolecular proton transfer(ESIPT)fluorescent probe was constructed by employing dimethylthiocarbamate group as the recognition unit and 4-hydroxy-2-(pyrlin-2-ylmethyl)isoindoline-1,3-dione as the fluorophore.The probe containing pyridinium salt group exhibited preeminent water-solubility and was employed to detect hypochlorous acid(HOCl)in full water solution.The protection of hydroxyl group with dimethylthiocarbamate blocked the ESIPT process,leading to the weak fluorescent of the probe.However,with the addition of HOCl,the dimethylthiocarbamate group was cleaved,releasing the hydroxyl group,leading to the fluorescence appeared due to the recovery of ESIPT process.The probe could detect HOCl in the linear range of 0-80μmol/L with the detection limit of 94 nmol/L.Additionally,the probe displayed fast response(4 min)and large Stokes shift(113 nm),and could be used for detection of HOCl in water samples and living cells.
关 键 词:荧光探针 次氯酸 激发态分子内质子转移 细胞成像
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145