检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李涌涛 赵昂 李建文[2] 车通宇 潘林 陈晨[2] LI Yongtao;ZHAO Ang;LI Jianwen;CHE Tongyu;PAN Lin;CHEN Chen(Xi'an Division of Surveying and Mapping,Xi'an 710054,China;Institute of Geospatial Information,Information Engineering University,Zhengzhou 450001,China)
机构地区:[1]西安测绘总站,陕西西安710054 [2]信息工程大学地理空间信息学院,河南郑州450001
出 处:《武汉大学学报(信息科学版)》2022年第1期69-78,共10页Geomatics and Information Science of Wuhan University
基 金:国家自然科学基金(41904042)。
摘 要:为了分析单站区域电离层总电子含量(total electron content, TEC)模型的适用范围和精度,基于2~15阶次球谐函数,分别建立了欧洲区域16个单站区域电离层TEC模型,生成了区域格网TEC,并与欧洲定轨中心(Center for Orbit Determination in Europe,CODE)、国际全球导航卫星系统服务组织(International Global Navigation Satellite System Service, IGS)和全球GNSS监测评估系统(International GNSS Monitoring and Assessment System, iGMAS)等全球电离层产品比较分析。结果表明,基于低阶(2×2阶或3×3阶)球谐函数建立的单站区域电离层TEC模型,以单站为中心,在经纬度10°×10°范围以内(半径小于600 km),电离层TEC精度与CODE、iGMAS和IGS等全球电离层产品的TEC精度相当,约为1.0 TECU,实现了在一定区域内(半径小于600 km)利用单站建立电离层TEC模型替代全球电离层TEC模型,高效地为区域内单频用户提供高精度的电离层延迟改正。Objectives:Establishing a regional ionospheric total electron content(TEC) model from a single station is much more efficient than developing a global multistation model because of its small amount of data. However, the single-station regional ionospheric TEC model has a scope of application. Therefore, the study of the scope and accuracy of a single-station regional ionospheric TEC model can effectively provide high-precision ionospheric delay correction for single-frequency users in the region. Methods:With 2-to15-order spherical harmonic functions, single-station regional ionospheric TEC models are established using global navigation satellite systems(GNSS) observations from 16 stations in the European region during day of year(DOY) 357—363 in 2017, a period of calm solar activity and without a magnetic storm. The average ionospheric TEC values and average root mean square(RMS) values at all grid points in the longitude–latitude ranges of 0°×0°, 10°×5°, 10°×10°, 10°×15°, 20°×15°, and 20°×20° are compared with those of global ionospheric products such as Center for Orbit Determination in Europe(CODE), International GNSS Monitoring and Assessment System(iGMAS), and International GNSS Service(IGS) for the determination of the scope of application and accuracy of the single-station regional ionospheric TEC models.Results:(1) The 16 single-station regional ionospheric TEC models based on 2-to-15-order spherical harmonic functions have the average TEC values within the value range of CODE, iGMAS, and IGS in different regions. In other words, within the latitude-longitude range of 20°×20°, the TEC values of the single-station regional ionospheric models established by the proposed method are comparable to those of CODE, iGMAS, and IGS.(2) The RMS values of regional ionospheric TEC models established with the data of 16 single stations and 2-to-15-order spherical harmonic functions are different from those of IGS beyond the latitude-longitude range of 10°×10°. The lower order of spherical h
分 类 号:P237[天文地球—摄影测量与遥感]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.129.218.83