检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张松斌 ZHANG Song-bin(Chongqing Water Resources and Electric Power Construction Survey Design and Research Institute Co.Ltd.,Chongqing 401120,China)
机构地区:[1]重庆市水利电力建筑勘测设计研究院有限公司,重庆401120
出 处:《水利科技与经济》2022年第3期118-121,共4页Water Conservancy Science and Technology and Economy
摘 要:以青杉水库面板混凝土冬季施工为例,提出3种面板混凝土裂缝防控施工方案。数值分析结果表明,在6℃~10℃的浇筑温度下,掺入微膨胀剂+厚8 cm聚苯乙烯泡沫塑料保温板进行保温,能够显著降低面板混凝土的早期开裂风险;在此施工环境下,不建议对面板混凝土进行配筋,同时还应尽量减少与垫层的约束,在混凝土养护期间应严格执行保温、保湿措施,直至水库蓄水。Taking the winter construction of panel concrete in Qingshan reservoir as an example,three construction schemes for crack prevention and control of panel concrete are proposed.The numerical analysis results show that,at the temperature of 6℃~10℃,the thermal cracking of the concrete with small expansion agent + 8 cm thick polystyrene foam insulation board can significantly reduce the early cracking risk of the panel concrete.In this construction environment,it is not recommended to reinforce the slab concrete,and at the same time,the constraint should be reduced as much as possible.During concrete curing,thermal insulation and moisturizing measures shall be strictly implemented until the reservoir is filled with water.
关 键 词:面板混凝土 微膨胀剂 聚苯乙烯泡沫塑料保温板 防裂措施 配筋 垫层约束
分 类 号:TV521[水利工程—水利水电工程]