锅炉铠装热电偶腐蚀爆管浅析  被引量:2

Brief analysis of corrosion explosion of boiler armored thermocouple

在线阅读下载全文

作  者:张幼林[1] 严建伟[1] ZHANG You-lin;YAN Jian-wei(Harbin Boiler Company Limited,Harbin 150046,China)

机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046

出  处:《锅炉制造》2022年第2期22-23,共2页Boiler Manufacturing

摘  要:某电厂投运一年左右后,检修时锅炉大包上方部分铠装热电偶发现有三分之二左右有不同程度的腐蚀,同时还有部分产品出现了爆管现象:本文详细分析腐蚀、爆管的原因及总结经验,给后续热电偶的安装提供借鉴。About one year after a power plant was put into operation,two-thirds of the armored thermocouples above the boiler package were found to be corroded in different degrees,and some of the products were found to be tube burst.In this paper,the causes of corrosion and tube burst are analyzed in detail,and the experiences are summarized to provide reference for the installation of thermocouple.

关 键 词:铠装热电偶 腐蚀 爆管 

分 类 号:TK223[动力工程及工程热物理—动力机械及工程]

 