精细化工10 kV及以下变配电所供配电设计要点  被引量:6

Main Points of Power Supply and Distribution Design for 10 kV and Below Substations in Fine Chemical Industry

在线阅读下载全文

作  者:袁涛 宋鹏飞 龚晓璐 YUAN Tao;SONG Pengfei;GONG Xiaolu(Hubei Yuanda Chemical Engineering Co.,Ltd.,Wuhan 430000,China)

机构地区:[1]湖北省缘达化工工程有限公司,湖北武汉430000

出  处:《现代建筑电气》2022年第2期29-33,共5页Modern Architecture Electric

摘  要:根据精细化工变配电所型式特点,结合国家标准规范,介绍了10 kV及以下变配电所供配电设计时要关注的要点问题。详细阐述了设计要点对应的标准条文内容,在供配电施工图设计中应严格执行标准条文,可以有效减少施工图设计的漏项,多方面完善施工图的设计深度。According to the type characteristics of the fine chemical substation and distribution station combined with national standards and specifications,the main points should be paid attention to when designing the power supply and distribution of 10 kV and below substations.This paper elaborates on the content of the standard provisions corresponding to the design points.The standard provisions should be strictly implemented in the power supply and distribution design of construction drawings.The missing items in the construction drawing design can be effectively reduced,and the design depth of construction drawings is improved from many aspects.

关 键 词:线路保护 电动机保护 10 kV开关柜 配电装置布置 油浸式变压器 柴油发电机 保护配置 

分 类 号:TU852[建筑科学]

 