作 者:郑立安 柳文波 Zheng Li'an;Liu Wenbo(Central and Southern China Municipal Engineering Design and Research Institute Co.,Ltd.,Wuhan 430010,China;Wuhan Urban Construction Investment&Development Group Co.,Ltd.,Wuhan 430063,China)
机构地区:[1]中国市政工程中南设计研究总院有限公司,湖北武汉430010 [2]武汉市城市建设投资开发集团有限公司,湖北武汉430063
出 处:《供水技术》2022年第1期50-53,共4页Water Technology
摘 要:对给水厂工程中清水池主要的设计要点进行总结,包括清水池容积、导流墙、配管、附属设施、水位等。建议在用地紧张的项目中将清水池叠建于絮凝平流沉淀池或其他构筑物之下,为其他类似新建、扩建、改建工程设计提供参考。The main design points of clean water tank in waterworks project were summarized, including clean water tank volume, diversion wall, piping, auxiliary facilities, water level, etc. It was suggested that the clean water tank could be built under the flocculation horizontal sedimentation tank or other structures in the project with land shortage, so as to provide reference for the design of other similar new construction, expansion and reconstruction projects.