作 者:聂永辉 刘天宇 蔡国伟[2] 高磊 吴奉瞳 王准航 NIE Yonghui;LIU Tianyu;CAI Guowei;GAO Lei;WU Fengtong;WANG Zhunhang(Academic Administration Office,Northeast Electric Power University,Jilin 132012,Jilin Province,China;College of Electrical Engineering,Northeast Electric Power University,Jilin 132012,Jilin Province,China;China Electric Power Research Institute,Haidian District,Beijing 100192,China;School of Mechatronic Engineering and Automation,Shanghai University,Baoshan District,Shanghai 200444,China)
机构地区:[1]东北电力大学教务处,吉林省吉林市132012 [2]东北电力大学电气工程学院,吉林省吉林市132012 [3]中国电力科学研究院有限公司,北京市海淀区100192 [4]上海大学机电工程与自动化学院,上海市宝山区200444
出 处:《电网技术》2022年第3期905-914,共10页Power System Technology
基 金:国家自然科学基金项目(61973072);国家重点研发计划项目(2016YFB0900104)。
摘 要:对于风电并网系统,双馈风电机组电网侧电压严重跌落容易在风机转子侧形成峰值涌流,损坏变流设备,并造成风机脱网。因此提出了模型预测转子电流控制(model predictive rotor current control,MP-RCC)与动态电压恢复器(dynamic voltage restorer,DVR)的协调控制策略,以提高双馈风机在故障情况下不脱网运行的能力。首先,根据双馈风电机组的工作原理,建立其预测控制状态空间模型;其次,在双馈风机转子侧施加MP-RCC,从而实现双馈风电机组低电压穿越时转子电流对参考值的迅速跟踪;最后,引入动态电压恢复器,在低电压穿越期间补偿电网压降,维持机端电压,以保证风电机组在MP-RCC控制下稳定运行。通过Matlab/Simulink对所提控制策略进行了仿真验证,结果表明,MP-RCC与DVR的协调策略可以有效应对双馈风电机组的低电压穿越过程,提高双馈风电机组的故障穿越能力。For the grid-connected wind power system, a severe voltage sag on the grid side of the doubly fed induction generators may induce a peak inrush current in the rotors,which damages the converters and causes wind turbine disconnection from the grid. To prevent these problems, we propose a strategy to coordinate the model predictive rotor current control(MP-RCC) and the dynamic voltage restoration for improving the ability of the wind turbines to remain its connection to the grid under faults. First, by considering the wind turbines operation, we establish a predictive control state-space model. Second, the MP-RCC is applied to the rotor of the wind turbines for the fast tracking of the rotor current to its reference value during the low-voltage ride-through. Finally,a dynamic voltage restorer compensates the grid voltage sag and maintains the terminal voltage during the low-voltage ride-through to ensure the stable operation of the wind turbines under the MP-RCC. Simulation results show that the proposed strategy to coordinate the MP-RCC and the dynamic voltage restoration effectively handles the low-voltage ride-through of the doubly-fed induction generators to improve the fault ride-through capability.
关 键 词:模型预测控制 双馈风电机组 电压跌落保护 低电压穿越 动态电压恢复器 转子电流
分 类 号:TM614[电气工程—电力系统及自动化]