检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:段梅子 谢军龙[1] 杨晖 赵志华 Duan Meizi;Xie Junlong;Yang Hui;Zhao Zhihua
机构地区:[1]华中科技大学能源与动力工程学院 [2]汇智工程科技股份有限公司武汉分公司
出 处:《洁净与空调技术》2022年第1期87-90,共4页Contamination Control & Air-Conditioning Technology
摘 要:针对洁净厂房净化空调系统特点及节能需求提出新风机组+单元化模块机组(MAU+FCFU)系统,并分析该系统与传统一次回风系统的全年运行能耗及机组设备所需功率等。结果表明,在系统各设备设计功率区别不大的情况下,与一次回风系统相比,MAU+FCFU系统节能效果显著。The make-up air unit+fan coil filter unit(MAU+FCFU)system is proposed according to the characteristics and energy saving requirements of clean-air conditioning system.By analyzing the annual operating energy consumption and the required power of the unit equipment of the MAU+FCFU system and the traditional primary return air system,the results show that the MAU+FCFU system has a significant energy saving effect compared with the primary return air system under the condition of little difference in air-conditioning components’required design capacities.
关 键 词:洁净厂房 净化空调系统 MAU+FCFU系统 节能
分 类 号:TU834.84[建筑科学—供热、供燃气、通风及空调工程]