摘 要:在我国目前电力系统体系中,其配电系统的核心是10kV电压等级的输变电系统,由于各种原因损耗巨大,因此对10kV配电网线路的线损率计算就显得尤其重要。本文主张在等值电阻的基础上进行改进,极大地简化了计算步骤,提高了理论线损计算精度,满足了实际需求。In China’s current power system,the core of its distribution system is the power transmission and transformation system at a voltage level of 10kV.Due to various reasons,the loss is huge,so the calculation of the line loss rate of the 10kV distribution network is particularly important.This article advocates an improvement on the basis of equivalent resistance,which greatly simplifies the calculation steps,improves the theoretical line loss calculation accuracy,and meets the actual needs.