基于改进等值电阻法的损耗计算方法  

Loss Calculation Method Based on Improved Equivalent Resistance Method

在线阅读下载全文

作  者:訾君 林凡平 Zi Jun;Lin Fan-ping(State Grid Huainan City Panji District Power Supply Company,Huainan 232082,Anhui Province,China)

机构地区:[1]国网淮南市潘集区供电公司,安徽淮南232082

出  处:《科学与信息化》2022年第7期86-88,共3页Technology and Information

摘  要:在我国目前电力系统体系中,其配电系统的核心是10kV电压等级的输变电系统,由于各种原因损耗巨大,因此对10kV配电网线路的线损率计算就显得尤其重要。本文主张在等值电阻的基础上进行改进,极大地简化了计算步骤,提高了理论线损计算精度,满足了实际需求。In China’s current power system,the core of its distribution system is the power transmission and transformation system at a voltage level of 10kV.Due to various reasons,the loss is huge,so the calculation of the line loss rate of the 10kV distribution network is particularly important.This article advocates an improvement on the basis of equivalent resistance,which greatly simplifies the calculation steps,improves the theoretical line loss calculation accuracy,and meets the actual needs.

关 键 词:等值电阻法 线路损耗 10KV 

分 类 号:TM7[电气工程—电力系统及自动化]

 