Structural optimization of patient-specific temporomandibular joint replacement implants for additive manufacturing:novel metrics for safety evaluation and biomechanical performance  

在线阅读下载全文

作  者:Manuel Pinheiro Anouar Krairi Robin Willaert Maria C.Costa Wim Van Paepegem 

机构地区:[1]Mechanics of Materials and Structures(MMS),Ghent University,Ghent,Belgium [2]Materials Innovation Institute(M2i),Delft,The Netherlands [3]Department of Oral and Maxillofacial Surgery,University [4]Hospitals Leuven,Leuven,Belgium 4 Department of Head and Neck Surgery,Ghent University Hospital,Ghent,Belgium

出  处:《Bio-Design and Manufacturing》2022年第2期333-347,共15页生物设计与制造(英文)

基  金:funding from the Interreg 2 Seas program 2014-2020 co-funded by the European Regional Development Fund under subsidy contract no.2S04-014。

摘  要:Total temporomandibular joint(TMJ)replacement is recommended only when there is irreversible damage to the joint and no conservative treatment can provide functional improvements.Several stock and custom-made TMJ implants have been made available;however,retrospective and comparative studies were unable to find significant differences between the two types of solutions.The introduction of additive manufacturing(AM)techniques in medical practice allows for a greater freedom of design and a higher degree of device customisation.The combination of AM with structural optimisation may streamline development and provide the key for fabricating biomechanic ally enhanced TMJ implants.In this study,structural optimis ation techniques were applied to develop and numerically validate a patient-specific TMJ implant.The biomechanical behaviour of each intermediate TMJ design was assessed under four different nominal and maximum biting tasks using finite element analyses.In addition,a new set of metrics were proposed to compare each design regarding biomechanical performance and implant safety.The results suggest that 55-82%of the natural/intact strain patterns can be recovered with the finally selected TMJ implant.This represents an increase of 15%in biomechanical performance for incisor biting,15%for right molar biting,17%for left molar biting and a decrease of 2%for left group biting compared with the initial design.The results also suggest that load transfer at the proximal ramus reduces the implant’s impact on the mandible’s strain patterns.Finally,structural optimisation allows for a volume reduction of up to 44%with a minimum loss of implant safety and biomechanical performance.

关 键 词:Temporomandibular joint Additive manufacturing Implant safety Biomechanical performance Finite element analysis 

分 类 号:R318.08[医药卫生—生物医学工程] R782.6[医药卫生—基础医学]

 