检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Francesco Pollari Ferdinand Vogt Irena Großmann Jill Marianowicz Marie Claes Steffen Pfeiffer Johannes Schwab Theodor Fischlein
机构地区:[1]Cardiac Surgery,Cardiovascular Center,Klinikum Nürnberg,Paracelsus Medical University,Nuremberg,Germany [2]Cardiology,Cardiovascular Center,Klinikum Nürnberg,Paracelsus Medical University,Nuremberg,Germany [3]Radiology,Klinikum Nürnberg,Paracelsus Medical University,Nuremberg,Germany
出 处:《Journal of Geriatric Cardiology》2022年第3期167-176,共10页老年心脏病学杂志(英文版)
摘 要:OBJECTIVES To assess the impact of prosthesis choice and aortic valve calcifications on the occurrence of conduction disturb-ances after transcatheter aortic valve implantation(TAVI).METHODS We retrospectively analyzed the preoperative clinical characteristics,electrocardiograms,contrast-enhanced mul-tidetector computed tomography scans and procedural strategies of patients who underwent TAVI in our center between January 2012 and June 2017.Quantification of calcium volume was performed for each aortic cusp above(aortic valve)and below(left ventricular outflow tract,LVOT)the basal plane.Multivariate analysis was performed to evaluate risk factors for the onset of new bundle branch block(BBB),transient and permanent atrioventricular block(tAVB,pAVB).RESULTS A total of 569 patients were included in the study.Six different prostheses were implanted(Edwards Sapien XT,n=162;Edwards Sapien 3,n=240;Medtronic CoreValve,n=27;Medtronic CoreValve Evolut R,n=21;Symetis Acurate,n=56;Sy-metis Acurate neo,n=63).The logistic regression analysis for BBB showed association with baseline left anterior hemiblock.The logistic regression for tAVB,found the prior valvuloplasty and the balloon post-dilatation associated with the outcome.Baseline left and right BBB,degree of oversizing,and LVOT calcification beneath the non-coronary cusp were associated with pAVB.Neither the prosthesis model,nor the use of a self-expandable prosthesis showed statistical significance with the above-men-tioned outcomes on univariate analysis.CONCLUSIONS LVOT calcification beneath the non-coronary cusp,baseline left anterior hemiblock,right BBB,balloon post-dilatation,prior valvuloplasty and oversizing are independently associated with postprocedural conduction disturbances after TAVI.Use of a self-expandable prosthesis may show a lower incidence of AVB,if applied in lower calcified aortic valves.
关 键 词:AORTIC BALLOON conduction
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49