Application of local Monte Carlo method in neutronics calculation of EAST radial neutron camera  被引量:1

在线阅读下载全文

作  者:Liangsheng HUANG Liqun HU Luying NIU Mengjie ZHOU Bing HONG Kai LI Ruixue ZHANG Guoqiang ZHONG 黄良胜;胡立群;牛璐莹;周梦洁;洪兵;李凯;张瑞雪;钟国强(Institute of Plasma Physics,Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031,People's Republic of China;University of Science and Technology of China,Hefei 230026,People's Republic of China;Sichuan Engineering Laboratory for Nuclear Facilities Decommissioning and Radwaste Management,Nuclear Power Institute of China,Chengdu 610005,People's Republic of China)

机构地区:[1]Institute of Plasma Physics,Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031,People's Republic of China [2]University of Science and Technology of China,Hefei 230026,People's Republic of China [3]Sichuan Engineering Laboratory for Nuclear Facilities Decommissioning and Radwaste Management,Nuclear Power Institute of China,Chengdu 610005,People's Republic of China

出  处:《Plasma Science and Technology》2022年第2期172-179,共8页等离子体科学和技术(英文版)

基  金:support and help in this research.This work was supported by Users with Excellence Program of Hefei Science Center CAS(No.2020HSC-UE012);Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228);National Natural Science Foundation of China(No.11605241)。

摘  要:The Local Monte Carlo(LMC)method is used to solve the problems of deep penetration and long time in the neutronics calculation of the radial neutron camera(RNC)diagnostic system on the experimental advanced superconducting tokamak(EAST),and the radiation distribution of the RNC and the neutron flux at the detector positions of each channel are obtained.Compared with the results calculated by the global variance reduction method,it is shown that the LMC calculation is reliable within the reasonable error range.The calculation process of LMC is analyzed in detail,and the transport process of radiation particles is simulated in two steps.In the first step,an integrated neutronics model considering the complex window environment and a neutron source model based on EAST plasma shape are used to support the calculation.The particle information on the equivalent surface is analyzed to evaluate the rationality of settings of equivalent surface source and boundary.Based on the characteristic that only a local geometric model is needed in the second step,it is shown that the LMC is an advantageous calculation method for the nuclear shielding design of tokamak diagnostic systems.

关 键 词:equivalent surface source radial neutron camera EAST local Monte Carlo method 

分 类 号:TL631.24[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象