Flip-over of blood vessel intima caused by vascular closure device:A case report  

在线阅读下载全文

作  者:Li-Xia Sun Xue-Song Yang Da-Wei Zhang Bo Zhao Lian-Lian Li Qi Zhang Qing-Zhi Hao 

机构地区:[1]The First Clinical Medical College,Shandong University of Traditional Chinese Medicine,Jinan 250000,Shandong Province,China [2]Department of Peripheral Vascular Diseases,the Affiliated Hospital of Shandong University of Traditional Chinese Medicine,Jinan 250000,Shandong Province,China

出  处:《World Journal of Clinical Cases》2022年第7期2247-2252,共6页世界临床病例杂志

基  金:Supported by the Traditional Chinese Medicine Science,No.2017-057,2017-058 and 2019-0969;Technology Development Project of Shandong Province,No.2019-0971

摘  要:BACKGROUND Complications of vascular closure devices mainly include bleeding,vascular injury,and trapped device that cannot be removed percutaneously.However,arterial stenosis or occlusion induced by vascular injury is rare.This article introduces a rare case with severe acute limb ischemia after using the vascular closure device(StarClose).CASE SUMMARY A 54-year-old man was admitted because of necrosis of the second toe of the left foot for 2 mo.Ultrasound showed left femoral artery stenosis,and occlusion of the left popliteal,posterior tibial,peroneal,anterior tibial and dorsalis pedis arteries,suggesting arteriosclerosis obliterans of low extremities,gangrene and type 2 diabetes.He underwent an interventional procedure of drug-eluting balloon in the left lower limb via antegrade puncture of the left common femoral artery.He developed acute limb ischemia after 1 h,and severe pain,numbness,pale skin,low skin temperature and weakened sensation in the left foot.Injury of the common femoral artery intima was considered.Exploratory surgery showed occlusion at the puncture point accompanied with bulged vascular lumen and flipped vascular intima caused by StarClose.The flipped intima was removed.The limb blood supply was restored and the limb was saved post-surgery.He recovered well at final follow-up.CONCLUSION Incorrect use of the vascular closure device was the main cause of severe acute limb ischemia in this case.

关 键 词:StarClose vascular closure device Vascular injury COMPLICATIONS Case report 

分 类 号:R969[医药卫生—药理学]

 