西门子Symbia T16 SPECT/CT故障维修与分析  被引量:5

Siemens Symbia T16 SPECT/CT fault maintenance and analysis

在线阅读下载全文

作  者:李迪[1] 张硕[1] 冯洪波[1] LI Di;ZHANG Shuo;FENG Hong-bo(Department of Nuclear Medicine,the First Affiliated Hospital of Dalian Medical University,Dalian 116011,Liaoning Province,China)

机构地区:[1]大连医科大学附属第一医院核医学科,辽宁大连116011

出  处:《医疗卫生装备》2022年第3期101-102,108,共3页Chinese Medical Equipment Journal

基  金:国家自然科学基金项目(81971693)。

摘  要:对西门子Symbia T16 SPECT/CT设备在使用过程中遇到的3例与探测器相关的故障进行了总结,详述了故障维修过程,探讨了故障发生的原因,为同类设备的维修与日常维护提供了参考。Three cases of detector-related faults encountered in the use of Siemens Symbia T16 SPECT/CT were summarized,the processes for maintenance were described in detail,and the causes of the faults were discussed.References were provided for the repair and routine maintenance of similar equipment.[Chinese Medical Equipment Journal,2022,43(3):101-102,108]

关 键 词:SPECT/CT 故障维修 故障分析 