检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李鹏[1] 何双亮[1] 周革强[1] 仇庆东 陈华[1] LI Peng;HE Shuangliang;ZHOU Geqiang;QIU Qingdong;CHEN Hua(China Astronaut Research and Training Center,Beijing 100094,China;Shenyang Xinghua Aero Electric Co.,Ltd.AVIC,Shenyang 110144,China)
机构地区:[1]中国航天员科研训练中心,北京100094 [2]中航工业沈阳兴华航空电器有限责任公司,沈阳110144
出 处:《载人航天》2022年第2期230-236,共7页Manned Spaceflight
摘 要:为提高小功率航天设备的可靠性,设计了一种基于高侧电流检测芯片的可恢复式的过流检测电路。采用硬件逻辑电路实现了反时限、定时限和瞬时速断保护曲线,对该电路进行仿真分析和验证,并对多级保护策略进行了讨论。结果表明:该电路结构简单、可靠性高,可灵活调整保护时间,其功能和性能均满足指标要求;采用多级分段保护的方式可提高电子系统的可靠性。To improve the reliability of low-power space equipment,a recoverable overcurrent detection circuit based on high-side current detection chip was designed.The inverse time-lag,fixed timelag and instantaneous quick-break protection curve were realized by using hardware logic circuit structure.In addition,the circuit was simulated,analyzed and verified.And the multi-level protection strategy was discussed.The results showed that the function and performance could meet the requirements,the circuit structure was simple,the reliability was high,and the protection time could be adjusted flexibly.The multi-level subsection protection was adopted to improve the reliability of the electronic system.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.170.88