机构地区:[1]中国医学科学院北京协和医院放疗科,北京100730
出 处:《中国医学装备》2022年第4期19-25,共7页China Medical Equipment
基 金:国家“十三五”重点研发计划(2016YFC0105206)“临床治疗与质量控制流程研究”。
摘 要:目的:研究在直肠癌术后辅助放射治疗中,基于Halcyon和Truebeam两种不同类型医用直线加速器设计的容积旋转调强治疗(VMAT)计划和固定野调强放射治疗(FF-IMRT)计划的计划质量和执行效率差异。方法:采用随机数表法选取在医院接受治疗的18例直肠癌术后患者,基于Halcyon和Truebeam医用直线加速器平台(简称Halcyon平台和Truebeam平台)分别设计VMAT和FF-IMRT计划,比较分析HalcyonVMAT、HalcyonFF-IMRT、TruebeamVMAT和Truebeam FF-IMRT 4种计划的剂量学指标[2%、98%体积受量(D_(2%)、D_(98%)),平均剂量(D_(mean)),10 Gy、20 Gy剂量线覆盖的相对体积(V_(10Gy)、V_(20Gy)),均匀指数(HI),梯度指数(GI)和适形指数(CI)]、机器跳数、执行时间、平均子野面积(MFA)和子野面积变异系数(CVA)等的差异,并进行射野剂量(PD)验证。结果:基于Halcyon平台和Truebeam平台设计的VMAT计划的D2%、GI及CI均优于FF-IMRT计划。两台加速器的VMAT和FF-IMRT共4种计划的靶区D_(2%)、D_(98%)和D_(mean)比较,差异有统计学意义(F=49.429,F=8.515,F=17.216;P<0.05);4种计划的HI、GI和CI比较,差异有统计学意义(F=38.979,F=32.636,F=68.220;P<0.05);4种计划的膀胱剂量指标的V_(10)、V_(20)和D_(mean)相比较,差异有统计学意义(F=15.178,F=13.183,F=8.487;P<0.05);4种计划执行效率的平均机器跳数、平均执行时间差异有统计学意义(F=251.012,F=175.276;P<0.05);HalcyonVMAT计划的复杂度指标MFA和CVA优于TruebeamVMAT计划,4种计划的MFA和CVA相比较差异有统计学意义(F=114.854,F=274.296;P<0.05),4种计划均通过PD验证。结论:在直肠癌辅助放射治疗中,基于Halcyon平台和Truebeam平台设计的VMAT计划相比于FF-IMRT计划均有较好的计划质量和较快的执行效率,Halcyon平台的VMAT计划相比于Truebeam平台的VMAT计划,在满足临床需求的同时能够降低计划的复杂度。Objective:To study the differences of plan quality and delivery efficiency of volumetric modulated arc therapy(VMAT)and fixed-field intensity-modulated radiation therapy(FF-IMRT)plans based on two kinds of designs of medical linear accelerator(Halcyon and Truebeam)for adjuvant radiotherapy after surgery for rectal cancer.Methods:18 postoperative patients with rectal cancer who received treatment in hospital were randomly selected by random number table method.VMAT plan and FF-IMRT plan were designed respectively based on Halcyon medical linear accelerator platform(Halcyon platform)and Truebeam medical linear accelerator platform(Truebeam platform).The differences of dosimetry indicators[2%volume dose(D_(2%)),98%volume dose(D_(98%)),mean dose(D_(mean)),relative volumes that were covered by 10Gy and 20Gy dose line(V_(10Gy),V_(20Gy)),homogeneity index(HI),gradient index(GI),conformity index(CI)],monitor units(MU),delivery time,mean field area(MFA),coefficient of variation of segments area(CVA)of 4 kinds of plans(VMAT and FF-IMRT of Halcyon platform,VMAT and FF-IMRT of Truebeam)were compared,and the portal dosimetry(PD)of them were verified.Results:The D_(2%),GI,CI of the VMAT plans based on Halcyon platform and Truebeam platform were all superior to FF-IMRT plans of them.The differences of D_(2%),D_(98%)and D_(mean) of target region among 4 kinds of plans were significant(F=49.429,F=8.515,F=17.216,P<0.05).The differences of HI,GI and CI among 4 kinds of plans were significant(F=38.979,F=32.636,F=68.220,P<0.05).The differences of V_(10Gy),V_(20Gy),and D_(mean) of bladder dose indicators among 4 kinds of plans were significant(F=15.178,F=13.183,F=8.487,P<0.05).The differences of average MU and average delivery time of execution efficiencies among 4 kinds of plans were significant(F=251.012,F=175.276,P<0.05).The MFA and CVA of complexity indicator of Halcyon VMAT plan were better than those of Truebeam VMAT plan.And the differences of MFA and CVA among 4 kinds of plans were significant(F=114.854,F=274.296,P<0.05).All 4
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...