检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曹侃 袁耀华 苏之勇 李小民[1] Cao Kan;Yuan Yaohua;Su Zhiyong;Li Xiaomin(School of Energy&Environment,Zhongyuan University of Technology,Zhengzhou 450007,China)
出 处:《低温与超导》2022年第3期47-50,65,共5页Cryogenics and Superconductivity
基 金:国家自然科学基金(21776263)资助。
摘 要:针对冷库冷藏系统夏季高温环境下出现压缩机排气温度较高、制冷性能降低等问题,设计并搭建了冷藏制冷系统实验台,研究了不同库外环境温度下系统制冷性能。结果表明:在库外高温工况下,补气系统相较于不补气压缩机排气温度降低了16.9%~18.4%,制冷量上升了12.8%~17.2%,压缩机功率增加了5.57%~6.51%,系统COP提升了6.93%~10.01%。For the problems of high exhaust temperature of compressor and low refrigeration performance in cold storage refrigeration system in summer,a refrigeration system experimental platform was designed and built,and the refrigeration performance of the system under different ambient temperatures outside the cold storage was studied.The results show that:under the high temperature condition outside the reservoir,the exhaust temperature of the air replenishing system decreases by 16.9%~18.4%,the refrigeration capacity increases by 12.8%~17.2%,the compressor power increases by 5.57%~6.51%,and the COP of the system increases by 6.93%~10.01%.
分 类 号:TH3[机械工程—机械制造及自动化]